4
GB
2.2 - aCCESSOriES SUppLiED wiTH THE UNiT
accessory
q
ty
Use
1
Wall support for the unit.
1 - Support plate
- Instructions
Installation instructions.
Operating instructions.
- Dowels
6
For fixing the support plate.
accessory
q
ty
Utse
6
For fixing the support plate
with the dowels.
4 - Screws
Connection of flexible tubes
on the installation
(Ø 1/" - 15 x 1)
5 - Seals
2.3 - wEiGHT
2.4 - DiMENSiONS
B
C
A
3 - iNSTaLLaTiON OF THE UNiT
3.1 - CHOOSiNG THE LOCaTiON
• Select the location for the unit on the basis of the following
criteria:
- The device is intended for installation in sheltered premises
(IP 0). Do not install in very damp places or exposed to
projHigh speedections of water.
- Do not place above electrical sockets.
- The air intake and blowing grilles must be free from any
obstacle so that blowing can occur correctly in the whole
room.
- The wall on which the air handler will be fixed must be
sufficiently thick for there not to be any resonance and so
as not to produce any noise.
- Provide for the pipes and electric cables.
- It is essential to leave the clear space around the unit (see
drawing).
3.2 - iNSTaLLaTiON OF THE SUppOrT pLaTE
• Remove the mounting screw
from the support plate.
• Press at the points indicated
by a triangle to unhook the
plate's two lugs.
• The unit may be connected at 5
different points:
- on either the right or left-hand
side,
- at either the right or left-hand
rear,
- on the lower right-hand side.
• Use the support plate as a jig to locate the rear outlets.
Place the plate level against the wall and mark the hole to be
made.
For an outlet at the left-hand rear of the unit, use the plate's
most outside mark.
The Ø 65 mm
h o l e i n t h e
u p p e r r i g h t -
hand corner of
the plate can
also be used
thus allowing
the tubes to exit
straight into the
wall.
• Mount the plate
on the wall using
the supplied
s c r e w s a n d
dowels.
T o
a v o i d
YES
NO
NO
Ø
65 mm (MPW1-2)
111
70
- Do not install units with electric heating near combustible
materials or surfaces.
vibrations, ensure that the panel is mounted securely against
the wall.
packed weight (kg)
10
14
Net weight (kg)
8
1
Mpw1-2
Mpw3-4
6 - Remote control unit 1 Remote control unit
A
B
C
MPW1-2
270
805
177
MPW3-4
285
995
206