6. ELECTRICAL DATA
6-1 Electrical characteristics
OUTDOOR UNIT:
GRF98L5TAA
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,12
0,28
3,00
3,40
Power input
Kw
0,027
0,063
0,680
0,770
Full load conditions
Running Amps.
A
0,12
0,28
3,60
4,00
Power input
Kw
0,027
0,063
0,790
0,880
NOTE: Data referred to indoor unit
MRAF98C5T
model.
For other indoor unit models there could be some differences.
OUTDOOR UNIT:
GRF128L5TAA
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,13
0,28
4,29
4,70
Power input
Kw
0,031
0,063
0,956
1,050
Full load conditions
Running Amps.
A
0,13
0,28
5,09
5,50
Power input
Kw
0,031
0,063
1,156
1,250
NOTE: Data referred to indoor unit
MRAF128C5T
model.
For other indoor unit models there could be some differences.
OUTDOOR UNIT:
GRF188L5TAA
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,37
0,41
6,32
7,10
Power input
Kw
0,070
0,087
1,443
1,600
Full load conditions
Running Amps.
A
0,37
0,41
7,72
8,50
Power input
Kw
0,070
0,087
1,793
1,950
NOTE: Data referred to indoor unit
MPAF188C5T
model.
For other indoor unit models there could be some differences.
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions: Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Outdoor unit
230V 1-Phase 50 Hz
Outdoor unit
230V 1-Phase 50 Hz
Outdoor unit
230V 1-Phase 50 Hz
43
Содержание GRF128L5TAA
Страница 24: ...Outdoor Unit GRF368L7TAA GRF488L7TAA dimension mm 24...
Страница 46: ...6 2 Electric Wiring Diagram GRF98L5TAA GRF128L5TAA GRF188L5TAA 46...
Страница 47: ...GRF188L7TAA GRF228L7TAA 47...
Страница 48: ...GRF258L7TAA GRF368L7TAA 48...
Страница 49: ...GRF488L7TAA 49...