Before reversing the cycle at the beginning and at the end of the defrost, the compressor ramps down to
decrease the pressure inside the circuit:
When defrost is active:
-
4-way valve is deactivated
-
Compressor runs at a fixed speed (if no protection is active)
-
EEV is open at a fixed value
-
Fan is off
When defrost ends:
-
4-way valve is reactiavted
-
EEV is opened at a fixed value for 5 minutes