Indoor Unit
MCA
60
1R
Outdoor Unit
GR
60
1R
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at 230 V Single phase 50 Hz
Rating Conditions Running Amps. A 0.37 0.55 9.08 10.0
Power Input kW 0.070 0.120 2.01 2.2
Full Load Conditions Running Amps. A 0.37 0.55 10.08 11.0
Power Input kW 0.070 0.120 2.21 2.4
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 46°C D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at 230 V Single phase 50 Hz
Rating Conditions Running Amps. A 0.37 0.55 9.28 10.2
Power Input kW 0.070 0.120 1.91 2.10
Full Load Conditions Running Amps. A 0.37 0.55 10.38 11.3
Power Input kW 0.070 0.120 2.13 2.32
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
: Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°CD.B. / 18°CW.B.
Full Load Conditions
18