2-3. Other Component Specifications
8
Power Relay (PR)
G7L-2A-TUB
Coil rating
AC 200 – 240V, 50/60Hz
Coil resistance
Ω
(at 23°C)
21 ± 15%
Contact rating
AC 220V, 25A
Outdoor Unit GR129C5
Transformer (TR)
ATR-H85
Rating Primary
AC 230V, 50/60Hz
Secondary
11V, 0.727A
Capacity
8VA
Coil resistance
Ω
(at 21°C)
Primary (WHT – WHT): 214 ± 10%
Secondary (BRN – BRN): 1.58 ± 10%
Thermal cut-off temp.
145°C, 2A, 250V
Thermistor (Coil sensor TH1) PBC-41E-S14
Resistance k
Ω
–20°C 40.1 ± 5% 20°C 6.5 ± 5%
–10°C 24.4 ± 5% 30°C 4.4 ± 5%
0°C 15.3 ± 5% 40°C 3.0 ± 5%
10°C 9.9 ± 5% 50°C 2.1 ± 5%
Thermistor (Room sensor TH2) KTEC-35-S6
Resistance k
Ω
10°C 10.0 ± 4% 30°C 4.0 ± 4%
15°C 7.9 ± 4% 35°C 3.3 ± 4%
20°C 6.3 ± 4% 40°C 2.7 ± 4%
25°C 5.0 ± 4% 50°C 1.8 ± 4%
Indoor Unit KPAV128C5