6 - ACCESSORIES
6.1 - WATER CONNECTION HOSES
• Length 1 m, insulated, female:
- Ø 3/4” code
70600054
for
PHRT 7
and
9,
- Ø 1” code
70600055
for
PHRT 12
and
16.
6.2 - CONDENSATE TANK HEATING CORD KIT (if not
factory installed)
• Code
70200055
.
• This accessory is recommended for units installed in where defrosting is
frequent.
• Remove the fan's protective grille (4 screws
A
).
• Remove the fan blade (nut
B
).
• Place the heating element in the bottom of the tank, as close as possible
to the fin tube exchanger.
• Position the isolated end on the left side and along the exchanger to the
back of the separating panel. Form a loop and return along the separating
panel.
• Use the aluminium adhesive strip to hold the heating cord in place, or as
required, metal clips welded in the tank.
• Pass the end of the heating cord through the grommet in the separating
panel with the fan wires.
• Connect the two wires on the printed circuit board between terminals 47
and 48.
Note:
The wire heats up over a length of 1.5 m.
Be sure not to place the heating portion in contact with the wires.
Make sure that the fan blade cannot come into contact with the
heating element.
A
A
A
A
B
1.50 m
1 m
Heating cord
location
Heating cord
Adhesive strips or clips
Black identifying mark
Heating portion
Non-heating
portion