GRV220C5TA-
Power source
Voltage rating
Performance *
MCAV220C5VA-
Capacity
kW
BTU/h
Air circulation (High)
m³/h
Moisture removal (High)
Liters/h
Electrical Rating
Available voltage range
V
Running amperes
A
Power input
W
Power factor
%
C.O.P.
W/W
Compressor locked rotor amperes
A
Features
Fan speed
Compressor
Refrigerant / Amount charged at shipment
g
Refrigerant control
Operation Sound
Hi
dB-A
Refrigerant tubing connections
Max. allowable tubing length at shipment
m
Refrigerant
Narrow tube
mm(in.)
tube diameter
Wide tube
mm(in.)
Dimensions & Weight
Unit dimensions
Height
mm
Width
mm
Depth
mm
Package dimensions
Height
mm
Width
mm
Depth
mm
Weight
Net
kg
Shipping
kg
Shipping volume
m
3
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Remarks:
Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
220 - 240V ~ 50Hz
230V
Cooling
198 ~ 264
830
Cooling
R407C / 2400
Capillary tube
1(Hi)
Rotary (Hermetic)
Flare type
7,5
6,35 (1/4")
15,88 (5/8")
835
850
305
913
1000
400
67,0
76,0
0,37
50
5,90
20134
3,3
13,00
2750
92
2,1
70
9
Содержание 387107059
Страница 19: ...4 REFRIGERANT FLOW DIAGRAM Indoor Unit Outdoor Unit GRV180C5TA Indoor Unit Outdoor Unit GRV180C5TAB 19...
Страница 20: ...Indoor Unit Outdoor Unit GRV180L5TA Indoor Unit Outdoor Unit GRV180L5TAB 20...
Страница 21: ...Indoor Unit Outdoor Unit GRV220C5TA 21...
Страница 37: ...6 2 Electric Wiring Diagram GRV180C5TA GRV180C5TAB OUTDOOR UNIT OUTDOOR UNIT GRV180L5TA 37...
Страница 38: ...GRV220C5TA OUTDOOR UNIT 38...
Страница 39: ...6 3 System Wiring Diagram 39...