2-2 Major Component Specifications
Outdoor Unit:
GRV72C5TA-
Compressor
Type
Compressor model
Nominal output
W
Compressor oil…Amount
cc
Coil resistance (Ambient temp. 25°C)
Ω
Overload relay
Safety devices
Type
Operating Temp. Open
°C
Close
°C
Operating amp. (Ambient temp. 25°C)
Run capacitor
µF
VAC
Fan & Fan Motor
Type
Q'ty ……. Dia.
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Nominal output
W
Coil resistance (Ambient temp. 25 °C )
Ω
Safety devices
Type
Operating temp. Off
°C
On
°C
Run capacitor
µF
VAC
Heat Exch. Coil
Coil
Rows
Fin pitch
mm
Face area
m
2
External Finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE
WHT-YEL: 408,1
1…. Ø 370
115 ± 3
FV68S…350
C-R: 4,66
145 ± 5
69 ± 11
CS-7C115
6…832
25,05
BRN-WHT: 242,4
802 060 35B C-1RN60H5C
600
95 ± 5
17,5
450
//
Acrylic baked-on enamel finish
Thermal protector
130 ± 5
1
1,3
0,353
1,5
Aluminium plate fin / Copper tube
450
Rotary (Hermetic)
83 ± 15
C-S: 8,89
Propeller
UE6-21ST5P…1
External (OLR T)
External (OLR A)
MRA 38072-3229
Trip in 6 to 16 s at 13 A
8