background image

0.8180.531.00     05/2007

IMPORTANT!
Please read before installation

This air conditioning system meets strict safety and operating
standards.
For the installer or service person, it is important  to install or
service the system so that it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state and national electrical  codes.
• Pay close attention to all warning and caution notices given in

this manual.

•The unit must be supplied with a dedicated electrical line.

This symbol refers to a hazard or unsafe practice which can result
in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can result
in personal injury or product or property damage.

If necessary, get help

These instructions are all you need for most installation sites and
maintenance conditions.
If you require help for a special problem, contact our sale/service
outlet or your certified dealer for additional instructions.

In case of improper installation

The manufacturer shall in no way be responsible for improper
installation or maintenance service, including failure to follow the
instructions in this document.

SPECIAL PRECAUTIONS

• During installation, connect before the refrigerant system and

then the wiring one; proceed in the reverse orden when removing
the units.

When wiring

ELECTRICAL SHOCK CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH. ONLY A QUALIFIED,
EXPERIENCED ELECTRICIANS SHOULD ATTEMPT
TO WIRE THIS SYSTEM.

• Do not supply power to the unit until all wiring and tubing are

completed or reconnected and checked, to ensure the grounding.

• Highly dangerous electrical voltages are used in this system.

Carefully refer to the wiring diagram and these instructions when
wiring.
Improper connections and inadequate grounding can cause

accidental injury and death

.

Ground the unit 

following local electrical codes.

• The Yellow/Green wire cannot be used for any connection

different from the ground connection.

• Connect all wiring tightly. Loose wiring may cause overheating

at connection points and a possible fire hazard.

• Do not allow wiring to touch the refrigerant tubing, compressor,

or any moving parts of the fan.

• Do not use multi-core cable when wiring the power supply and

control lines. Use separate cables for each type of line.

When transporting

Be careful when picking up and moving the indoor and outdoor
units. Get a partner to help, and bend your knees when lifting to
reduce strain on your back. Sharp edges or thin aluminium fins on
the air conditioner can cut your fingers.

When installing...
... In a ceiling or wall

Make sure the ceiling/wall is strong enough to hold the unit-weight.
It may be necessary to build a strong wooden or metal frame to
provide added support.

... In a room

Properly insulate any tubing run inside a room to prevent
"sweating", which can cause dripping and water damage to walls
and floors.

... In moist or uneven locations

Use a raised concrete base to provide a solid level foundation for
the outdoor unit.
This prevents damage and abnormal vibrations.

... In area with strong winds

Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.

... In a snowy area (for heat pump-type systems)

Install the outdoor unit on a raised platform that is higher than
drifting snow. Provide snow vents.

When connecting refrigerant tubing

• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare

and union tubes before connecting them;  screw by hand and
then tighten the nut with a torque wrench for a leak-free
connection.

• Check carefully for leaks before starting the test run.

NOTE:

Depending on the system type, liquid and gas lines may be either
narrow or wide. Therefore, to avoid confusion, the refrigerant
tubing for your particular model is specified as narrow tube for
liquid, wide tube for gas.

When servicing

• Turn the power OFF at the main power board  before opening

the unit to check or repair electrical parts and wiring.

• Keep your fingers and clothing away from any moving parts.
• Clean up the site after the work, remembering to check that no

metal scraps or bits of wiring have been left inside the unit being
serviced.

• Ventilate the room during the installation or testng the refrigeration

system; make sure that, after the installation, no gas leaks are
present, because this could produce toxic gas and dangerous
if in contact with flames or heat-sources.

WARNING

CAUTION

WARNING

2

Содержание 38.7107.080

Страница 1: ...ATA SERVICE MANUAL OUTDOOR UNIT GRF78R5TAA GRF98R5TAA GRF128R5TAA 0 8180 552 1 06 2008 SPLIT SYSTEM AIR CONDITIONER GRF128R5TAA 38 7107 082 Model No Product Code No GRF98R5TAA 38 7107 081 GRF78R5TAA 3...

Страница 2: ...t allow wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of...

Страница 3: ...er Component specifications 11 3 DIMENSIONAL DATA 12 4 REFRIGERANT FLOW DIAGRAM 13 5 PERFORMANCE DATA 14 5 1 Performance Charts 14 5 2 Cooling Capacity 17 5 3 Heating Capacity 20 6 ELECTRICAL DATA 21...

Страница 4: ...RANGE Cooling Maximum Minimum 43 C D B 19 C D B 32 C D B 23 C W B 19 C D B 14 C W B 24 C D B 18 C W B 8 C D B 9 C W B Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Heating Maximum Minimum...

Страница 5: ...tube diameter Wide tube mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO...

Страница 6: ...ube mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTIC...

Страница 7: ...ube mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTIC...

Страница 8: ...ominal output W Coil resistance Ambient temp 25 C Safety devices Type Operating temp Open C Close C Run capacitor F VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish DATA SUBJECT...

Страница 9: ...W Coil resistance Ambient temp 25 C Safety devices Type Operating temp Open C Close C Run capacitor F VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish DATA SUBJECT TO CHANGE WIT...

Страница 10: ...W Coil resistance Ambient temp 25 C Safety devices Type Operating temp Open C Close C Run capacitor F VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish DATA SUBJECT TO CHANGE WIT...

Страница 11: ...2 3 Other Component Specifications GRF78R5TAA GRF98R5TAA GRF128R5TAA 4 way Valve 20S Coil rating Coil resistance at 20 C AC 220 240 V 50 Hz 6W 1470 7 SQ 136 Coil SHF 4H 23U Valve 11...

Страница 12: ...IONAL DATA 700 540 15 470 4 12 holes 116 320 294 Air intake Air discharge 255 10 170 103 57 Narrow tube service valve 6 35 1 4 Wide tube service valve 9 52 3 8 12 7 1 2 7000 9000 BTU h 12000 BTU h Uni...

Страница 13: ...ditioner become cold To prevent heat loss and wet floors due to dripping of condensation both tubes must be well insulated with a proper insulation material The thickness of the insulation should be a...

Страница 14: ...00 4 50 10 5 0 5 10 15 20 25 Outdoor inlet air D B C High pressure at wide tube service valve MPa 2 5 2 7 2 9 3 1 3 3 3 5 3 7 3 9 20 25 30 35 40 45 Outdoor inlet air D B temp C Operating current A In...

Страница 15: ...5 20 25 Outdoor inlet air D B C High pressure at wide tube service valve MPa 2 7 2 9 3 1 3 3 3 5 3 7 3 9 20 25 30 35 40 45 Outdoor inlet air D B temp C Operating current A Indoor inlet air D B C 32 27...

Страница 16: ...5 20 25 Outdoor inlet air D B C High pressure at wide tube service valve MPa 4 0 4 5 5 0 5 5 6 0 6 5 7 0 20 25 30 35 40 45 Outdoor inlet air D B temp C Operating current A Indoor inlet air D B C 32 27...

Страница 17: ...0 1 75 TC 2 47 2 34 2 26 2 15 2 02 1 86 CM 0 34 0 42 0 49 0 56 0 64 0 71 21 SHC 1 09 1 02 0 99 0 94 0 89 0 82 23 SHC 1 29 1 20 1 17 1 13 1 07 1 00 19 25 SHC 1 48 1 38 1 35 1 30 1 25 1 18 27 SHC 1 67 1...

Страница 18: ...05 2 88 2 78 2 65 2 49 2 29 CM 0 55 0 59 0 64 0 68 0 72 0 77 21 SHC 1 35 1 26 1 22 1 16 1 09 1 01 23 SHC 1 59 1 48 1 45 1 39 1 32 1 24 19 25 SHC 1 83 1 70 1 66 1 61 1 54 1 46 27 SHC 2 06 1 92 1 89 1...

Страница 19: ...3 91 3 70 3 57 3 40 3 19 2 94 CM 0 69 0 78 0 87 0 97 1 06 1 15 21 SHC 1 73 1 62 1 57 1 49 1 40 1 30 23 SHC 2 04 1 90 1 86 1 78 1 69 1 59 19 25 SHC 2 35 2 18 2 14 2 06 1 98 1 87 27 SHC 2 64 2 46 2 42 2...

Страница 20: ...lowing rating condition Indoor 20 C D B Outdoor 7 C D B 6 C W B 2 Above characteristics indicate instantaneous operation which does not take into consideration defrost operation 3 Fan speed High 4 Bec...

Страница 21: ...C D B 23 C W B Outdoor Air Temperature 43 C D B HEATING Indoor Unit Complete Unit Fan Motor Fan Motor Compressor performance at Rating conditions Running Amps A 0 11 0 28 2 51 2 90 Power input Kw 0 02...

Страница 22: ...r Temperature 43 C D B HEATING Indoor Unit Complete Unit Fan Motor Fan Motor Compressor performance at Rating conditions Running Amps A 0 12 0 28 3 20 3 60 Power input Kw 0 027 0 063 0 700 0 790 Full...

Страница 23: ...ir Temperature 43 C D B HEATING Indoor Unit Complete Unit Fan Motor Fan Motor Compressor performance at Rating conditions Running Amps A 0 13 0 28 4 8 5 20 Power input Kw 0 031 0 063 0 931 1 025 Full...

Страница 24: ...6 2 Electric Wiring Diagram GRF78R5TAA GRF98R5TAA GRF128R5TAA 6 3 System Wiring Diagram indoor unit MRAF78R5TAA outdoor unit GRF78R5TAA MRAF98R5TAA GRF98R5TAA MRAF128R5TAA GRF128R5TAA 24...

Страница 25: ...T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728 R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France...

Отзывы: