5-5 Dry Mode Operation
Dry operation remove moisture from indoor air running, in cooling mode, at a low level without reducing the
ambient temperature. This is done cycling ON and OFF indoor and outdoor units according to below.
ROOM
DRY LEVEL
TEMP
≥
SPT+2°C
LEVEL 0
Operation according to COOLING mode
CM on at constant speed
< SPT+2°C
LEVEL 1
FMO on at constant speed
≥
SPT-1°C
FMI switches between L and LL every 30 seconds
RV off
CM switches 9 minutes off and 3 minutes on
< SPT-1°C
LEVEL 2
FMO switches 9 minutes off and 3 minutes ON
≥
15°C
FMI switches between L and LL every 30 seconds
RV off
CM off
< 15°C
DRY OFF ZONE
FMO off
FMI off
RV off
SPT = Set Point Temperature
5-6 Fan Mode Operation
With this mode, the indoor fan is turned on while CM, FMO and RV stay off all the time. The user can select
between 3 speeds: HIGH, MEDIUM and LOW.
5-7 Auto Fan speed
With this option selected, the indoor fan speed changes automatically according to the compressor speed:
as shown in the following graphs
to prevent the supply of cool air, the FMI speed is setted as shown only if the indoor coil temperature ICT
≥
32°C
( see COLD DRAFT PREVENTION feature for details )
13
Содержание 38.7104.063
Страница 7: ...2 DIMENSIONAL DATA 7...
Страница 9: ...4 ELECTRICAL DATA 4 1 Electric Wiring Diagrams 9...
Страница 24: ...6 3 SYSTEM DOES NOT RUN 24...
Страница 25: ...6 3 SYSTEM DOES NOT RUN 25...
Страница 26: ...6 4 OUTDOOR UNIT DOES NOT RUN AND NO FAULT IS DISPLAYED 6 5 ONLY OUTDOOR UNIT IS OFF 26...
Страница 28: ...6 7 AIR CONDITIONER OPERATES BUT ABNORMALITIES ARE OBSERVED 28...
Страница 29: ...3 CHECK MODE BUTTON OPERATION ON THE UNIT Push the mode button The unit does not run PCB assy is defective 29...
Страница 30: ...6 8 NOISY PROBLEM Pagina 30...
Страница 31: ...7 CHECKING ELETRICAL COMPONENTS 7 1 31...
Страница 32: ...7 2 32...