Technibel Climatisation MCAF124R5IAA Скачать руководство пользователя страница 19

19

Setting the Timer (continued)

3. How to set the ON time

(Example) To start operation at 7:10 am.

4. How to set DAILY ON/OFF 

REPEAT timer

(Example) To start operation at 7:10 am. and stop the air conditioner at 11:00 
am.

To cancel a timer program

Press the CANCEL button.

When either an ON or OFF timer is to be canceled, press the button 
corresponding to the timer whose program is to be canceled, and then 
press the CANCEL button.

The airflow direction, fan speed and temperature setting can be changed 
after a timer program has been set even when the unit is stopped. Even 
when operation is stopped during an ON timer program, the unit will start 
operating when the set time is reached provided that the program is not 
canceled.

When the ON timer and OFF timer are set to the same time, the timer 
operates as if it is turned off.

 

Operation

Indication

1.

Press the ON TIME setting 
button once.

The timer 

 indication is 

displayed, and the present ON time 
is shown.

2.

Press the Advance, Return ( , 

) button until AM 7:10 is 

displayed.

The timer 

 indication blinks.

The time can be set in 10-minute 
increments. Holding down the 
button advances the time rapidly in 
10-minute increments.

3.

Wait a few seconds, and then 
the setting is complete.

The timer 

 indication stops 

blinking and the present time is 
displayed.

7:10 am. 

ON

11:00 am. 

OFF

10:30 pm. 

Present time

 

1.

Set the timer ON/OFF times as 
shown in 2-1, 2, 3 and 3-1, 2, 3.

The present time 10:30 pm. and 

 are displayed.

The ON/OFF combination timer uses the current time as 
the reference, and it is activated starting from whichever 
set time comes first.

With the ON/OFF combination timer, the settings are 
repeated every day.

You can check the timer ON/OFF times after you have set 
them by pressing the ON TIME and OFF TIME setting 
buttons.

NOTE

NOTE

Содержание MCAF124R5IAA

Страница 1: ...r conditioner system Acondicionador de aire de consola partida sistema split Climatiseurs split Split klimager t Condizionatore d aria split system Save These Instructions Guard is estas instrucciones...

Страница 2: ...utlet directing air in a sweeping motion around the room and providing comfort in every corner Auto Flap Control This automatically sets the flap to the optimum position during heating cooling and dry...

Страница 3: ...d serial numbers are on the nameplate on the bottom of the cabinet Model No ______________________ Serial No ____________________ Date of purchase ________________________________________________ Deal...

Страница 4: ...o not install this air conditioner where there are fumes or flammable gases or in an extremely humid space such as a greenhouse Do not install the air conditioner where excessively high heat generatin...

Страница 5: ...is blown out of the air conditioner through the air outlet Remote Control Unit The wireless remote control unit controls power ON OFF operation mode selection temperature fan speed timer setting and...

Страница 6: ...ed DRY orange COOL green and FAN green mode The OPERATION lamp lights up red and orange alternately when the system is defrosting TIMER lamp This lamp lights when the system is being controlled by the...

Страница 7: ...m Timer ON Timer OFF Timer 1 hour OFF Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7 Auto flap indication Flap angle indication Sweep indication 8 High power operation 9 Quiet operation Displa...

Страница 8: ...u press the buttons on the remote control unit the mark appears in the display to transmit the setting changes to the receiver in the air conditioner Sensor A temperature sensor inside the remote cont...

Страница 9: ...e control unit will automatically adjust the set temperature to save energy FLAP button Press this button either to select the setting of the airflow direction to the auto flap in each mode or one of...

Страница 10: ...should not be bent The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals If the signal from the remote control unit stops for more than 15 minu...

Страница 11: ...from the remote control unit every 5 minutes Mounting the Remote Control Unit Before mounting the remote control unit press the ON OFF operation button at the mounting location to make sure that the...

Страница 12: ...ode is selected and the unit is preset by following the steps below you can have the air conditioner automatically bring the room to the desired temperature simply by pressing the ON OFF operation but...

Страница 13: ...or heating operation For dehumidifying operation For cooling operation For fan only operation STEP 2 To start the air conditioner press the ON OFF operation button STEP 3 Press the TEMP setting button...

Страница 14: ...s In the event of power failure the unit will stop 3 Adjusting the Fan Speed A Automatic fan speed Simply set the FAN SPEED selector button to the position This automatically sets the best fan speed f...

Страница 15: ...the indoor temperature when night setback was selected This enables you to save energy without sacrificing comfort This function is convenient when gentle cooling is needed Setting temperature Press...

Страница 16: ...the indoor unit for all operation modes except automatic operation Press the HIGH POWER button The mark appears in the display To cancel press HIGH POWER button again When the HIGH POWER button is pr...

Страница 17: ...e alternately until defrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms Co...

Страница 18: ...ance Return button until PM 10 30 is displayed The time can be set in 1 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Press the CLOCK button again This...

Страница 19: ...timer operates as if it is turned off Operation Indication 1 Press the ON TIME setting button once The timer indication is displayed and the present ON time is shown 2 Press the Advance Return button...

Страница 20: ...nues to operate for one hour from that point in time and then stops It is not possible to use the OFF Timer and 1 Hour OFF Timer together Whichever function is set last takes precedence If the 1 HR TI...

Страница 21: ...osition position until the air being blown out of the unit begins to warm Once the air warms up the flap position and fan speed change to the settings specified with the remote control Use the FLAP bu...

Страница 22: ...aning 2 Do not pour water on the indoor unit to clean it This will damage the internal components and cause an electric shock hazard Casing and Grille Indoor Unit Clean the casing and grille of the in...

Страница 23: ...nd dry it How to replace the anti mold filter 1 With the FRONT mark of the anti mold filter at the front align the two indentions near the mark with the hooks at the rear of the air intake grille and...

Страница 24: ...n filters cannot be washed and reused Purchase a replacement filter at your local dealer Cleaning the main unit and remote control unit Wipe clean using a soft dry cloth To remove stubborn dirt moiste...

Страница 25: ...many people in room 2 Eliminate heat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat or cold out 4 Obstacle near air intake or air discharge port 4 Remove it to ensure...

Страница 26: ...ified without prior notice Per garantire un costante miglioramento dei nostri prodotti ci riserviamo di modificarli senza preavviso Par souci d am lioration constante nos produits peuvent tre modifi s...

Отзывы: