OUTDOOR UNIT:
GRF368L7TAA
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,92
1,34
4,34
6,60
Power input
Kw
0,210
0,29
2,802
3,300
Full load conditions
Running Amps.
A
0,92
1,34
5,14
7,40
Power input
Kw
0,210
0,29
3,402
3,900
NOTE: Data referred to indoor unit
CAF368C5T
model.
For other indoor unit models there could be some differences.
OUTDOOR UNIT:
GRF488L7TAA
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,92
1,34
7,44
9,70
Power input
Kw
0,210
0,29
4,502
5,000
Full load conditions
Running Amps.
A
0,92
1,34
9,34
11,60
Power input
Kw
0,210
0,29
5,902
6,400
NOTE: Data referred to indoor unit
CAF488C5T
model.
For other indoor unit models there could be some differences.
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions: Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Outdoor unit
230V 1-Phase 50 Hz
Outdoor unit
230V 1-Phase 50 Hz
45