Control Panel Menu 

Use the fixture’s Control Panel to access the Control Menu.  The MODE Key puts the 
fixture in the settings menu itself and also acts as a BACK key between options, 
UP/DOWN moves through the menu options and allows the assignment of a value. The 
ENTER key is used to enter that option and confirms the selection once the UP/DOWN 
is used to adjust the value. When in edit, the display will Flash. Settings are stored and 
recalled on subsequent power cycles. R, G, B refers to Red, Green, and Blue 
respectively. DMX and master/slave modes require data cables to be connected between 
fixtures. Manual and some stand-alone modes do not require data cables for 
independent use of the fixture.  The display will shut off after 30 seconds, press any 
button to relight it.  

 

 
Note:

  The factory default CHANNEL MODE is set to “05” the 5 channel DMX mode. 

 

DMX-512 Control

 

Fixtures require a "Start Address" from 1 to 512, setting the first DMX channel containing data 
for the fixture (see DMX Background).  Before addressing fixtures, consult the manual of the 
system’s DMX controller to select a desirable addressing scheme.  Valid Start Addresses range 
from 1 to 512.  Fixtures requiring more than one channel for control will read subsequent 
channels up to the total number of channels required.  Since this fixture requires 5 channels of 
DMX, if set to a Start Address of 6 it would use data from channels: 6, 7, 8, 9 and 10.  Choose a 
Start Address so the channels used do not overlap with other fixtures.  In some cases, it may be 
desirable to set two or more same type fixtures to the same Start Address.  In this case, the 

Menu Options 

Function 

Options 

DMX MODE 

 

 

ADDR 

Select DMX Start Address 

01-512 

CHANNEL 

Select Number of DMX Operating Channels  03 = 3 channels or 05 = 5 channels 

DIMMER 
CURVE 

Selects dimming curve 

01 – linear response LED 
02 – linear response Halogen 
 

STATIC 

Allows a static scene to be set 

R00G00B00  F00 

set R 0-255, G 0-255, B 0-255, Flash speed 

from 00 to 99 

 

CHANGE 

7 Color change scroll 

SP01-99  F00-99 

Sets color change speed from 01-99 
Set flash speed from 00-99 

 

CHANG3 

3 Color change scroll 

SP01-99  F00-99 

Sets color change speed from 01-99 
Set flash speed from 00-99 

 

DREAM 
 

Color fading 
 

SP01-99  F00-99 

Sets color change speed from 01-99 
Set flash speed from 00-99 

 

SOUND 
 

Set audio sensitivity 

SENS:00-31 

MASTER/ 
SLAVE MODE 

Selects master or slave mode 

MASTER

: master fixture 

SLAVE

: slave fixture 

Содержание FlexiLED Series

Страница 1: ...Information specifically for DL FLEXILED100TC B V1 0 This manual contains important information Please read before operating fixture...

Страница 2: ...d to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer...

Страница 3: ...7 DMX Data Connection 8 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignments 9 3 Channel Mode 03 9 5 Channel Mode 05 9 Channel Values and Functions 5 Channel Mode 10 CH 1...

Страница 4: ...unting hole Physical Color Black Size 12 W x 8 75 H x 13 L Weight 9 5 lbs 4 32 kgs Housing Material Aluminum Environmental Location Indoor Min distance to flammable surface 3 3ft 1m Min distance to il...

Страница 5: ...of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non...

Страница 6: ...utput beam of the fixture By using certain light diffusers it is possible to create different desired lighting effects A desired effect might be a softer or diffused light beam Many diffraction materi...

Страница 7: ...dressing scheme Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixt...

Страница 8: ...inator connect a 120 ohm watt resistor across pin 2 Data Negative S and pin 3 Data positive S Whether it is a 5 pin XLR or 3 pin XLR connector shown on right does not matter the pin numbers remain the...

Страница 9: ...e previous fixture s Start Address to its channel requirement 1 5 6 To maximize channel usage we will leave no empty channels between fixtures so the second Start Address is set to DMX channel 6 and t...

Страница 10: ...ls the actual output level while the relative level of each color is set by the R G or B channels CH 5 Effect The effect DMX channel selects between normal sound activation or strobe flashing operatio...

Страница 11: ...or effects 3 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 4 Inspect clamps and safety cables to ensure fixture is secu...

Страница 12: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...

Отзывы: