background image

Immediately upon receipt, carefully unpack and inspect the unit to verify that all parts are 
present and have been received in good condition. If any parts appear damaged from shipping 
or the shipping carton shows signs of mishandling, retain all packing material for inspection and 
notify the shipper immediately. Save all original packing and carton. In the event that the 
merchandise is to be returned, the original carton and packing must be used.  The customer will 
be billed for a new carton and packing if merchandise is received without the original carton and 
packing.  The plastic bag shipped with the unit can be used to keep the unit clean if stored or 
installed in a temporarily dusty environment. Do not operate unit with plastic bag in place. 

The packing and carton are designed to provide the unit with protection during 
shipping.  Save original packing and documentation for warranty, service and return 
issues. Additional charges will be applied to return items not received in original or 
incomplete packing.

Returned merchandise must be sent prepaid, in the original packing with a Return 
Merchandise Authorization number (RMA) clearly listed on the shipping label. Items 
sent by Freight Collect or without a RMA number will be refused.  Call your sales 
person and request a RMA prior to shipping. Be prepared to provide the model number, 
serial number and a brief description of the nature of the return. Shipping damage 
resulting from inadequate packaging is the customer’s responsibility. Customer will be 
charged additional shipping charges to return products received in non original packing 
and or cartons.

Physical damage must be reported to the Freight Carrier or Shipping Company upon 
receipt of merchandise. Damage incurred in shipping is the responsibility of the Freight 
Carrier or Shipping Company. It is the customer's obligation in the event that 
merchandise is received damaged caused by shipping to notify the Freight Carrier or 
Shipping Company immediately. All other claims not related to damage incurred during 
shipping must be made to the Dealer or Distributor within 7 (seven) days of receiving 
merchandise. 

UNPACKING

SAFETY INSTRUCTIONS

Save shipping materials

Claims

Returns

3

!

WARNING!!! To reduce the risk of fire, electric shock, or injury to 
persons, follow these important safety instructions:

  This product is intended for indoor use only! 

  Always turn off, unplug power and allow unit to cool before servicing.

Содержание DL-ULEDDRIVER12R

Страница 1: ...Information specifically for DL ULEDDRIVER12R ...

Страница 2: ...EATURES SPECIFICATIONS PRODUCT VIEW SETUP Installation Unit Linking DMX Background Adapter 5 to 3pin AC Power OPERATING INSTRUCTIONS Menu Map System Setup System mode DMX mode Auto mode Sound mode Master Slave Fuse Replacement Specifications 2 3 3 4 4 4 4 4 4 5 5 6 6 7 7 8 8 8 9 9 9 9 10 ...

Страница 3: ...2 DL ULEDDRIVER12R ...

Страница 4: ...horization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to shipping Be prepared to provide the model number serial number and a brief description of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be char...

Страница 5: ...re consultation Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the unit To prevent risk of fire or shock do not expose unit to rain or moisture The unit must be installed in a location with adequate ventilation at least 5cm from adjacent surfaces Be sure no ventilation slots are...

Страница 6: ... more units in master slave operating mode you need DMX cables to link the units from DMX IN to DMX OUT 0 1 DL ULEDMR16TC9 DL ULEDMR16INS DL ULEDMR16LSS DL ULEDMR16TC3 DL ULEDMR16WW3 DL ULEDMR16CW3 DL ULEDFLEX TC DL ULEDBAR3TC6 IMPORTANT 1 The units are linked in serial Open circuit will cause malfunction 2 Always connect OUT 1 of Splitter with a ULED unit and OUT 2 to the next Splitter SPLITTER ...

Страница 7: ...z However the input voltage MUST be selected on the back of the unit prior to applying power to the mains Warning The unit must be connected to a circuit with a suitable Earth Ground Caution Wrong voltage will cause permanent damage to the unit which is not covered in warranty ...

Страница 8: ...mmer 000 255 Prog18 Dimmer 000 255 Prog 18 Gold Prog 19 step change Prog19 speed 01 10 Prog19 Dimmer 001 255 Prog 20 cross fade Prog 21 strobe Prog 22 chasing System Mode Sound Sound Program 01 Sensitivity 01 Enter Sensitivity 01 Sound Program 02 Enter Sensitivity 01 Sound Program 03 System Setup new software Down Up Menu Map Power Menu Enter Up Down DMX Control Panel When navigating the menu Use ...

Страница 9: ...igned for factory to upload software through USB port Your product has been tested before shipment Check with local distributor or dealer s web site if updated software is available System Mode xxx Press MENU button until display reads System Mode XXX then use UP DOWN button to scroll through DMX Slave Auto Sound DMX Mode In DMX mode each output port takes up 6 DMX channels You can address all por...

Страница 10: ...am to the beat of music Step color changing and color chasing are available in Sound mode 1 Press Menu button until display reads System Mode xxx use Up Down button to select sound program 2 Press Enter button to reach Sensitivity and use Up Down to adjust sensitivity level 9 Master Slave Mode For large venue multiple systems can be run in sync as Master Slave Use DMX cables to link the Drivers to...

Страница 11: ...mpact on human health and the environment ensure that this product is recycled at the end of its life SPECIFICATIONS Output Port 1 8 48V DC 350mA 36W Port Max Port 9 12 48V DC 144W Port Max Total load 12 ports 450W Max Power Input AC 120 60Hz 240V 50Hz switchable Size 19 x 9 9 x 3 46 2U Rack 482mm x 252mm x 88mm Weight 6 0kgs 13 20lbs ...

Страница 12: ...10900 Palmbay Drive Orlando FL 32824 U S A Voice 407 857 8770 Fax 407 857 8771 www techni lux com ...

Отзывы: