background image

 5

Unpacking 

Immediately upon receipt, carefully unpack and inspect the fixture to verify that all parts are 
present and have been received in good condition.  If any parts appear damaged from shipping 
or the shipping carton shows signs of mishandling, notify the shipper immediately.  Retain 
carton and all packing material for inspection.  In the event that the merchandise is to be 
returned, the original carton and packing must be used.  The customer will be billed for a new 
carton and packing if merchandise is received without the original carton and packing. 
 

Claims 

Physical damage must be reported to the Freight Carrier or Shipping Company upon 
receipt of merchandise.  Damage incurred in shipping is the responsibility of the Freight 
Carrier or Shipping Company.  It is the customer’s obligation in the event that 
merchandise is received damaged, to notify the Freight Carrier or Shipping Company 
immediately.  All other claims not related to damage incurred during shipping must be 
made to the Dealer or Distributor within 7 days of receiving merchandise.  

 

Returns 

Returned merchandise must be in the original packing with a Return Merchandise 
Authorization number (RMA) clearly listed on the shipping label.    Items sent by Freight 
Collect or without a RMA number will be refused.   Call your sales person and request a 
RMA prior to shipping.  Be prepared to provide the model number, serial number and 
description of the nature of the return.  Shipping damage resulting from inadequate 
packaging is the customer’s responsibility.  Customer will be charged additional shipping 
charges to return products received in non original packing and or cartons. 

 
 

Power 

 

Do not apply power to the fixture until power source is verified. 

 

For protection against electric shock, fixture must be connected to suitable earth ground. 
Make sure fixture is disconnected from power mains before any service. 

 
The mains voltage and frequency of this fixture is automatically set. It may operate on an input 
AC voltage ranging from 100 to 250volts, 50/60Hz.  The listed power rating is its average 
wattage under normal conditions. All fixtures must be powered directly from a switched circuit.  
This fixture cannot be run on a rheostat or dimmer circuit even if used solely for a 0% to 100% 
switching.  Before applying power to a fixture, check that the fixture’s input voltage matches the 
power source voltage.  Consult a qualified electrician if there are any concerns about proper 
connection to power. 
 
 

 

 

 

 

 

Содержание DL-QUADBAR430TC

Страница 1: ...Information specifically for DL QUADBAR430TC v1 0 This manual contains important information Please read before operating fixture...

Страница 2: ...to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Страница 3: ...01 P14 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 Invert Function 8 DMX Operation 9 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Ad...

Страница 4: ...1 x 7 1 Weight 8 8 lbs 4 0 kgs Housing Material Aluminum and steel Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminat...

Страница 5: ...urn Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to sh...

Страница 6: ...ket may be used to floor stand this unit or mount on wall Mounting holes are provided on each bracket to help accommodate a clamp Always keep cords out of the way thus preventing any trip hazards Secu...

Страница 7: ...fixture you can select one static color or from 13 different program chases Each program is described in the table below To select a program Press the MODE button to select the internal PROGRAM Mode S...

Страница 8: ...the MODE button to select the AUTO Mode Press the ENTER button to select the desired frequency of the loops The desired frequency of the loops Frequency FQN 01 99 can be selected using the UP DOWN but...

Страница 9: ...Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required In 5 channel mode the fixture...

Страница 10: ...dress that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wis...

Страница 11: ...nnels Bar completely operates as 1 complete section only Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 5 channels Bar completely operates as 1 complete section only with additional Master dimmer strobing and so...

Страница 12: ...Strobe 0 255 R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 Master Dimmer 0 255 5 000 000 On No F...

Страница 13: ...ster dimmer 72 79 Color 1 Master dimmer 80 87 Color 2 Master dimmer 88 95 Color 3 Master dimmer 96 103 Color 4 Master dimmer 104 111 Color 5 Master dimmer 112 119 Color 6 Master dimmer 120 127 Color 7...

Страница 14: ...or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secur...

Страница 15: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...