14

Maintenance 

Make sure fixture is cool and disconnected from power mains before any service. 

 

 

Weekly operating hours and environmental conditions will establish how often the fixtures need 
cleaning.  Fixtures should be cleaned and inspected at least once a month to maintain optimum 
performance.  Accumulation of dust and fog residue increases heat build up, can lead to 
malfunctions, overheating and reduction in maximum light output, reduced fixture life and over 
all performance.  Before conducting any maintenance, disconnect fixture from power mains.   
  
1) Disconnect fixture from power mains. 
2) Use a vacuum with a soft brush to remove dust collected on external vents, heat sinks and 
internal components.  If using an air compressor, use low pressures and extreme care to 
prevent damaging any internal parts or effects. 
4) Clean all optical elements when the fixture is cold.  Use a soft lint free cotton cloth or tissue 
and cleaner safe for plastics.  
5) Inspect clamps and safety cables to ensure fixture is secure and safe. 
 
 

Accessory Items 

(sold separately)

 

 

Order Code 

Description 

CLAMP-MEGA/B 

Mega Heavy Duty Aluminum Clamp – Black 

CLAMP-CBHALF 

Half Cheeseborough Coupler 300kg Max Load  

 

 

SAFETYCABLE18B 

Safety Cable Black 18” 

SAFETYCABLE18S 

Safety Cable Silver 18” 

 

 

CA-XLR5/5 

Pre-made 5’  5-pin XLR Cable 

CA-XLR5/10 

Pre-made 10’ 5-pin XLR Cable 

CA-XLR5/25 

Pre-made 25’ 5-pin XLR Cable 

 

 

CA-XLR3/5 

Pre-made 5’ 3-pin XLR Cable 

CA-XLR3/10 

Pre-made 10’ 3-pin XLR Cable 

CA-XLR3/25 

Pre-made 25’ 3-pin XLR Cable 

 

 

CO-XLR5M   

XLR Connector 5-pin Male 

CO-XLR5F 

XLR Connector 5-pin Female 

CO-XLR3M   

XLR Connector 3-pin Male 

CO-XLR3F 

XLR Connector 3-pin Female 

 

 

CO-XLRTERM5 

XLR 5 Pin Data Terminator 

CO-XLRTERM3 

XLR 3 Pin Data Terminator 

 

 

CO-XLR3MTO5F 

XLR 3 Pin Male to 5 Pin Female Adapter 

CO-XLR5MTO3F 

XLR 5 Pin Male to 3 Pin Female Adapter 

 

 

Содержание DL-OBAR830TC

Страница 1: ...Information specifically for DL OCTOBAR830TC v1 0 This manual contains important information Please read before operating fixture...

Страница 2: ...to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Страница 3: ...01 P14 7 Auto Run Operation 8 Slave Operation 8 Sound Active Operation 8 Invert Function 8 DMX Operation 9 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Ad...

Страница 4: ...x 7 1 Weight 13 64 lbs 6 2 kgs Housing Material Aluminum and steel Environmental Location Indoor Max ambient temperature 113 F 45 C Min distance to flammable surface 3 3ft 1m Min distance to illuminat...

Страница 5: ...urn Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA prior to sh...

Страница 6: ...ket may be used to floor stand this unit or mount on wall Mounting holes are provided on each bracket to help accommodate a clamp Always keep cords out of the way thus preventing any trip hazards Secu...

Страница 7: ...fixture you can select one static color or from 13 different program chases Each program is described in the table below To select a program Press the MODE button to select the internal PROGRAM Mode S...

Страница 8: ...the MODE button to select the AUTO Mode Press the ENTER button to select the desired frequency of the loops The desired frequency of the loops Frequency FQN 01 99 can be selected using the UP DOWN but...

Страница 9: ...Valid Start Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required In 5 channel mode the fixture...

Страница 10: ...dress that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wis...

Страница 11: ...3 Ch 1 2 3 Ch 1 2 3 5 channels Bar completely operates as 1 complete section only with additional Master dimmer strobing and sound control channels Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2...

Страница 12: ...CH 26 CH 27 R5 G5 B5 R6 G6 B6 R7 G7 B7 R8 G8 B8 Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 Master Dimmer 0 255 5 000 000 On No F...

Страница 13: ...ster dimmer 72 79 Color 1 Master dimmer 80 87 Color 2 Master dimmer 88 95 Color 3 Master dimmer 96 103 Color 4 Master dimmer 104 111 Color 5 Master dimmer 112 119 Color 6 Master dimmer 120 127 Color 7...

Страница 14: ...or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secur...

Страница 15: ...all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the...

Отзывы: