DMX-512 Control

 

Fixtures require a "Start Address" from 1 to 512, setting the first DMX channel containing data 
for the fixture (see DMX Background).  Before addressing fixtures, consult the manual of the 
system’s DMX controller to select a desirable addressing scheme.  Valid Start Addresses range 
from 1 to 512.  Fixtures requiring more than one channel for control will read subsequent 
channels up to the total number of channels required.  Since this fixture requires 7 channels of 
DMX, if set to a Start Address of 7 it would use data from channels: 7, 8, 9, 10, 11, 12, and 13.  
Choose a Start Address so the channels used do not overlap with other fixtures.  In some 
cases, it may be desirable to set two or more same type fixtures to the same Start Address.  In 
this case, the fixtures will be slaved together and respond to the same data.  Because all 
fixtures see the same data, fixtures may be set to any address without concern for the order 
they are connected by the DMX cables.   

 
Note:

 For DMX to operate on this unit, all STANDALONE options must be set to Off. 

 

DMX Data Connection 

This fixture uses 5 pin XLR type connectors and shielded twisted pair cable approved for 
EIA-422/EIA485 use.  Fixtures are connected in Daisy Chain topography:  Connection is 
made from the controller to the DMX-IN of the first light, then from the DMX-OUT to the 
DMX-IN of the next light and so on.  Only one data source can be on a chain and no 
branching is allowed.  The physical order in which the fixtures are connected is not 
important, use the most convenient.  

 
 
 
 
 
 
 
 
 
 

Data Terminator 

A Data Terminator can be connected to the DMX-OUT of the 
last fixture to reduce the effects of signal noise; it is not required 
for all installations. To make a Terminator, connect a 120-ohm 
¼ watt resistor across pin 2, Data Negative (S-) and pin 3, Data 
positive (S+). Whether it is a 5 pin XLR or 3 pin XLR connector 
(shown on right) does not matter, the pin numbers remain the 
same. A qualified technician can determine if a Data Terminator 
is needed. 

 

 

DMX-IN



3
4
5

 
 
 

- Ground
- Signal (-)
-
-
-

 
 
 

S

(Unused)

ignal 

 

(+)

XLR Connector - Plug:

1

2

3

4

5

DMX-OUT

XLR Connector - Socket:



3
4
5

 
 

- Ground
- Signal (-)
-
-
-

 
 

S

(Unused)

ignal 

 
 

(+)

1

2

3

4

5

Содержание DL-FLEXILED1C30/B

Страница 1: ...1 Information specifically for DL FLEXILED1C30 B Black V1 1 This manual contains important information Please read before operating fixture...

Страница 2: ...d to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer...

Страница 3: ...hannel Assignments 8 Fixture Mode DMX512 8 4 Channel Mode 8 5 Channel Mode 8 6 Channel Mode 8 7 Channel Mode 9 Channel Values and Functions 7 Channel Mode 9 DMX 512 Control 11 DMX Data Connection 11 D...

Страница 4: ...nting hole Physical Color Black Size 11 x 12 0 x 10 Weight 8 8 lbs 4 kgs Housing Material Aluminum Environmental Location Indoor Max ambient temperature 105 F 40 C Min distance to flammable surface 3...

Страница 5: ...hipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cart...

Страница 6: ...using a frosted gel within the provided frame Many diffraction materials are available to create different beam angles with minimal light output losses Setup and Operation Modes LCD Display The follow...

Страница 7: ...Sets the display to be on only when active On Off Reset Reset System Sure Red 0 255 Green 0 255 Blue 0 255 Test White 0 255 Scene01 08 Red 0 255 Green 0 255 Blue 0 255 White 0 255 Prog Scene Strobe 0...

Страница 8: ...nnel Mode Adds Master Dimmer 03 6 Channel Mode Adds Master Dimmer and Strobe 04 7 Channel Mode Adds Master Dimmer and Macro Using the 7 channel mode provides the most features however it takes up the...

Страница 9: ...tual value is subject to Master Dimmer channels The Color Macro Scroll Channel will override this channel CH 5 White Sets relative intensity of White Actual value is subject to Master Dimmer channels...

Страница 10: ...8 11 Lt Blue 12 15 Blue 16 19 Purple 20 23 Blue Magenta 24 27 Magenta 28 31 Hot Pink 32 35 Pink 36 39 Red 40 43 Orange 44 47 Yellow 48 51 Lime 52 55 Lt Green 56 59 Green 60 63 Teal 64 67 Cyan 68 71 C...

Страница 11: ...Note For DMX to operate on this unit all STANDALONE options must be set to Off DMX Data Connection This fixture uses 5 pin XLR type connectors and shielded twisted pair cable approved for EIA 422 EIA4...

Страница 12: ...Your choices are 4 5 6 or 7 channel modes This will determine the spacing of channels you will need to avoid overlapping of channels when selecting your start addresses Example Select Start Addresses...

Страница 13: ...all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessor...

Страница 14: ...mitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard...

Отзывы: