DMX-512 Background 

DMX-512 is a digital data transmission standard developed by the United States Institute for Theater Technology 
(USITT).  It is designed to enable control of lighting equipment.  DMX deals solely with the formatting of data for 
transmission and does not dictate how the data is created or used. 
 
Under DMX, signals are transmitted in much the same way a computer modem transmits data.  The Data, divided 
into channels, is "Framed" using a start bit, high (1), eight data bits and finally, two stop bits, both high (1). DMX 
uses  no  parity  to  check  the  integrity  of  the  signal.    Instead,  DMX  relies  on  the  ultra  low  probability  of  an  error 
occurring in the same place when the data is resent.  The rate at which data is sent is fixed at 250k bps, almost 
four and a half times faster that a 56k modem.   This speed allows all data on a DMX chain to be updated more 
than 44 times every second. 
 
The transmitted data follows a specific format. DMX allows for 512 channels each with eight data bits, giving each 
channel the possibility of 256 values.  When a data "Packet" is sent, all channels are transmitted one after another. 
 Even if the data on a specific channel has not been changed, it must be sent.  In a packet, a "start code" of all 
zeros is sent before the data to identify the signal as a Standard DMX transmission.  This start code is transparent 
to the user and is handled by the controller. 
 
The  physical  signals  are  transmitted  using  a  twisted  pair  of  wires  and  a  common  shield,  a  configuration  called 
Balanced.  The controller and all receiving equipment are connected using a “Daisy Chain" connection.  The signal 
is jumped from the controller to a piece of DMX equipment.  From there, the signal is jumped to the next piece of 
equipment and so on until the last piece of equipment is connected.  No branches are allowed and the signal does 
not come back to the controller.  The final piece of equipment will have only one cable connection.  As a result, all 
equipment  connected  to  the  chain  will  see  exactly  the  same  signal  whether  it  is  first  or  last.    When  connecting 
equipment, no particular attention needs to be paid to the order in which the equipment is connected.  Depending 
on the conditions and equipment, a line terminator may be required.  If there is any question, in most circumstances 
the addition of a terminator will not degrade the signal.  To make a terminator, attach a 120-ohm resistor between 
the Signal Data Negative and Signal Data Positive pins of a connector in the last piece of equipment in the chain. 
 
The DMX Standard uses 5 pin XLR connectors.  However, it is common to see 
fixtures with 3 pin XLR connectors as these types of balanced or “Lo-Z” cables 
are  common  in  the  audio  industry.    In  either  case,  pin  numbers  are  the  same 
and carry the same signals.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pin 

Connection 

Common (Shield) 

Data Negative (S- or Cold) 

Data Positive (S+ or Hot) 

n/c (not used) 

n/c (not used) 

Содержание bSCULPT 200 LED

Страница 1: ...bSCULPT 200 LED Profile LED Ellipsoidal Information specifically for TH SCLPB200WW B V1 1 This manual contains important information Please read before operating fixture...

Страница 2: ...ted to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the deale...

Страница 3: ...t and GOBO Holder 8 Basic Setup Wiring Diagrams 8 Fixture Menu LED Display 9 NOTE 9 Remote Device Management RDM 10 DMX 512 Control 10 DMX Data Connection 10 Data Terminator 10 Adapters for 3 or 5 pin...

Страница 4: ...n IP20 Indoor Min Max Ambient Temperature 5 to 105 F 20 to 40 C Min distance to flammable surface 3 3 ft 1 0 m Min distance to illuminated surface 1 0 ft 0 3 m Electrical Voltage Auto Ranging 100 240V...

Страница 5: ...shipping charges to return products received in non original packing and or cartons Purpose of Manual The purpose of this manual is to explain the necessary steps for using this fixture properly and...

Страница 6: ...d ventilation exposure to water high humidity and extreme temperature changes Fixture may be mounted in any orientation provided appropriate clamp is used to mount securely A Secondary Mounting posito...

Страница 7: ...ition to prevent color frames from accidentally falling when unlocked 3 Reinstall Focus Knobs adjust lens back and forth to set desired focus and gently retighten knobs Beam Chart Approximate Diameter...

Страница 8: ...metal or glass gobos Basic Setup Wiring Diagrams There are two basic ways to use the fixture One is in standalone which does not require the use of any data lines to be connected nor any controller e...

Страница 9: ...set desired VALUE Select Save again to Save and Exit Dimmer Curves alter the actual output level vs dimmer level to match different types of dimmers similar to audio faders with linear audio logarith...

Страница 10: ...Addresses range from 1 to 512 Fixtures requiring more than one channel for control will read subsequent channels up to the total number of channels required Since this fixture requires a maximum of 10...

Страница 11: ...esses Example Select Start Addresses for 4 fixtures each requiring 3 channels of DMX For this example start with the first unit set to the first possible Start Address 1 This fixture occupies DMX chan...

Страница 12: ...0 255 Dimmer 0 100 2 Dimmer Curve Speed 000 063 Curve 1 064 127 Curve 2 128 191 Curve 3 192 255 Curve 4 3 Strobe 000 009 Full Open 010 255 Strobe Level Slow to Fast 3a CHANNEL MODE Channel Function Va...

Страница 13: ...to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and s...

Страница 14: ...rent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receivin...

Страница 15: ...pin XLR Cable CA XLR5 25 Pre made 25 5 pin XLR Cable CO XLRTERM3 XLR 3 Pin Data Terminator CO XLRTERM5 XLR 5 Pin Data Terminator CO XLR3MTO5F XLR 3 Pin Male to 5 Pin Female Adapter CO XLR5MTO3F XLR 5...

Страница 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com...

Отзывы: