AIMA3000.FT5P Product User Manual
Technetix Group Limited
•
technetix.com
May/2016 - Version 1.0
49
STAT is
Amber
Operating environment Temperature is lower
or higher.
Check the Fans, or lower the room
temperature. If the temperature is normal,
please contact Technetix technical support.
+12V /+5V /-5VInput Voltage is lower or higher.
Please contact Technetix technical support.
RF input is lower or higher.
Adjust input signal or adjust MGC to an
appropriate value.
Laser Warning ALM or Laser shutdown. (“Laser
Output Status Alarm ”is set “Enable Minor”)
Check the laser’s status.
STAT is
red
Operating environment Temperature is too high
or too low.
Check the Fans, or lower the room
temperature. If the temperature is normal,
please contact Technetix technical support.
+12V /+5V/-5V Input Voltage too high or
too low.
Please contact Technetix technical support.
RF input power too high or too low.
Adjust input signal or adjust MGC to an
appropriate value.
Laser Critical ALM or Laser shutdown. (“Laser
Output Status Alarm ”is set “Enable Major”)
Check the laser’s status.