Table 6-2 for A-EDFA-x-x-G-x
Items
Sub Items
Description
Effect and Configuration Method
Configuration
Module Information
Slot
-
-
Module Type
-
-
Status
Output Status
Green indicates output status red
indicates no output
-
Laser Type
-
-
Configuration
Unit Control
Control Unit Switch
ON / OFF
Output Power Set
Set the optical output power based on
customer needs
16 ~ 24 dBm
Gain Per Wavelength
Alarm Settings
Output Status Alarm
-
-
Critical High
Alarm level setting, alarm parameters can be changed
Warning High
Warning Low
Critical Low
Dead Band
Parameters
Units
Critical
High
(HIHI)
Warning
High (HI)
Normal
Warning
Low (LO)
Critical
Low
(LOLO)
Dead
Band
Threshold
changeable
by user
Default
alarm
enable
Input power
dBm
16.0
15.0
-
-1.0
-2.0
0.1
Y
ON
Output
power
dBm
19.0
18.0
-
1.0
0.0
0.1
Y
ON
Laser output
power
dBm
19.0
18.0
-
1.0
0.0
0.1
Y
ON
Laser
Temperature
°C
35.0
30.0
-
20.0
15.0
0.1
Y
ON
Laser Bias
Current
mA
1300
1200
-
30
20
5
Y
ON
Laser TEC
Current
mA
2000
1500
-
-1500
-2000
20
Y
ON