background image

8

2018-08/EN V1

Technetix Group Limited

Product user manual

AIMA-RFSW

4.1.3 Rear panel view

Figure 4-3 Rear panel layout

Table 4-2 FPAS rear panel functions

Item Number

Item

Description

1

Input In A

RF input A

Input In B

RF input B

3

RF out

RF output

4

Air vent

Air vent allowing air to flow out of the module

5

Multi-pin connector

Power and communcation port

6

Placement Pin

Used to position the module in the chassis

Содержание AIMA-RFSW

Страница 1: ...AIMA RFSW RF A B PROTECTION SWITCH Online Email customer service vdl technetix com Website technetix com 2018 08 EN V1 Technetix Group Limited Product user manual...

Страница 2: ...Order details 5 4 Module characteristics 6 4 1 Module appearance and port layout 6 4 1 1 Overview 6 4 1 2 Front panel layout 7 4 1 3 Rear panel layout 8 5 Installation 9 5 1 Preparatory work for insta...

Страница 3: ...larm 18 6 4 3 Module port alarms 19 6 5 Alarm monitoring configuration 20 6 5 1 Monitoring function ON OFF 20 6 5 2 Temperature 12V 5V voltage alarm level management 21 6 5 3 Input Output status monit...

Страница 4: ...ent System Product User Manual NMS3 EPSM Basic Inventory Management NMS3 EPSM Basic Alarm Management NMS3 EPSM Basic System Management NMS3 EPSM Basic Template Management 1 2 Technical Support If you...

Страница 5: ...may be dangerous voltage inside the device DO NOT power up before the cover and the panels of the equipment are installed and the enclosure is closed Cleaning Only use a damp cloth to clean the front...

Страница 6: ...M AIMA3000 System Management Module within the AIMA3000 chassis The switching action may be set to by automatic or manual operation When in manual mode the switch can be controlled through the ASMM s...

Страница 7: ...output port 20 1 dB RF connectors 3 x GSK type female RF test points 3 x Mini SMB Switching time 15 ms Alarms and status Front panel LEDS and SNMP traps General Power supply Powered via AIMA3000 backp...

Страница 8: ...1 Technetix Group Limited Product user manual AIMA RFSW 3 3 1 Block Diagram Figure 3 1 RFSW block diagram 3 4 Order Details A RFSW Z RF A B protection switch Options Z Bandwidth 1G 45 1000 MHz Standar...

Страница 9: ...6 2018 08 EN V1 Technetix Group Limited Product user manual AIMA RFSW 4 Module Characteristics 4 1 Module Appearance and Port Layout 4 1 1 Overview Figure 4 1 Module appearance...

Страница 10: ...rking mode indicator Select input A light blinking 1 time per second Normal Green Minor Alarm Orange Major Alarm Red 4 RF 1 IN TP Input A testing point 5 RF 2 IN LED Input B working mode indicator Sel...

Страница 11: ...nel layout Table 4 2 FPAS rear panel functions Item Number Item Description 1 Input In A RF input A 2 Input In B RF input B 3 RF out RF output 4 Air vent Air vent allowing air to flow out of the modul...

Страница 12: ...uipment and tools for installation Table 5 1 Necessary equipment and tools for installation 5 2 Unpacking Unpack the module Keep the packaging materials for future transport needs Check the package ma...

Страница 13: ...he multi pin connector DO NOT use excessive force when inserting the module but ensure the RF connectors at the rear of the module are securely connected with the chassis s RF connectors CAUTION The m...

Страница 14: ...5 5 Test the RF Input Signal Measure the RF level at RF 1 IN TP Add 20 dB to the RF reading to compensate for RF loss Set the RF settings in RFSW page in the ASMM s web interface Measure RF 2 IN TP at...

Страница 15: ...ation methods For NMSE configuration methods please refer to the NMSE network management software manual 6 1 Port Configuration screen After the logging in to the AIMA ASMM controller s web interface...

Страница 16: ...the RFSW will automatically switch to Path B when no critical high or low alarms exist on Path B Path B Input limits can be set by configuring the parameters for the Critical Alarm and Low Alarm When...

Страница 17: ...ured as shown in Figure 6 1 Click Apply to the right of the Factory Default label in the commands section When finished the device configuration will be reset For more detailed factory reset informati...

Страница 18: ...th B Path A Same as the configuration before upgrade Wait to Restore Time 1 10 s 10 s Same as the configuration before upgrade 6 3 Reboot The module can be made to reboot remotely shown in Figure 6 2...

Страница 19: ...n Module Information Model HW Assembly No FW Version Firmware version Serial No FW Part No Firmware package number Configuration Alarm Control Control Alarm Indicator ON OFF Enable Disable Alarm Setti...

Страница 20: ...alarm occurs view the associated pages to find more detailed alarm information 6 4 1 Alarm Status Pages Click the Alarms tab on the top menu bar to display an overview of the alarm status of all the i...

Страница 21: ...on the left column under Alarms tab the operator can view the module temperature and supply voltage alarms The operator can utilize the status indicators to judge whether the module is working proper...

Страница 22: ...ms Click on Port under the associated RFSW from the left column as shown in Figure 6 5 From the Port screen the operator can view the Input Total Power and the Input Level alarms status There are thre...

Страница 23: ...Limited Product user manual AIMA RFSW 6 5 Alarm monitoring configuration 6 5 1 Monitoring Function ON OFF The Monitoring Function is labeled as Alarm Control and it can be toggled from the Configurat...

Страница 24: ...text in the text box will be solid black When the check box is unchecked detection OFF the text in the text box will be light gray and cannot be changed The default parameters are shown in Table 6 2...

Страница 25: ...left menu and the monitoring parameters are listed in the Alarm Settings section Click the to toggle the alarms The monitoring parameters can be changed by the user See Figure 6 7 below Parameters Cri...

Страница 26: ...Critical ALM Critical Alarm Module Status Critical Alarm STAT Red AM Minor ALM Warning Alarm Module Status Warning Alarm STAT Orange RF input Critical ALM RF Input Power Critical Alarm RF Input Power...

Страница 27: ...Product user manual AIMA RFSW 6 6 Logs management The operator can view all the alarms of the modules in the chassis on the Logs Management page Click Logs on the top menu bar to enter the Logs Manage...

Страница 28: ...Figure 6 9 The upgrade file needs to be located on the PC that is connected to the ASMM The RFSW supports automated firmware updates and automatic backup restore features through TFTP when managed vi...

Страница 29: ...status Common Faults Trouble Shooting RF IN A B status is Red Channel A B Input level is too high or too low Adjust channel A B input signal STAT is Red Channel A B Input level is too high or too low...

Страница 30: ...IMA RFSW Parameters Critical High Warning High Normal Warning Low Critical Low Dead Band Factory Default Temperature C 70 0 65 0 0 0 5 0 2 0 ON 5V Input Voltage V 6 5 0 4 4 0 1 ON 12V Input Voltage V...

Страница 31: ......