If  two  units  match  successfully  in  16  seconds,  indoor  monitor  displays 

Success”,  outdoor  unit  makes  “Beep-  Beep-Beep”  sounds,  as  the  first 

outdoor unit 

 

If matching failed in 16 seconds, indoor monitor shows “failed”, the outdoor 

unit makes ”Beep” sound 

 

Press “EXIT” key on the indoor monitor, exit menu, enter into the standby 

mode 

 

Note: If failed match, rematch the code after connection, otherwise, rematch 

the code after clear the code 

1.  Indoor monitor clear code method: refer to the menu function -

network -

Leave the network 

2.  Outdoor unit clear code method: 

A. Transformer supply: long press “Reset” key about one second, code cleared 

after a “tick” sound. 

B.  Battery  supply:  press  “Reset”  key  and  “doorbell  key”  at  the  same  time  till  a 

“Beep”, code cleared. 

 

Pairing Additional Monitors or outdoor unit 

NOTE:  By  default,  the  monitor  is  paired  with  the  outdoor  unit.  These 

instructions apply to paring a second or third monitor. 

 

Start  the  network  &  Join  the  network  (match  more  indoor  monitors  and 

outdoor units ): 

 

Choose “Start the network” on the old indoor monitor -

press “OK” key-

enter into “Start the network” mode 

 

Added indoor monitor enters into the network menu -

choose “Leave the 

network” -

press “OK” key -

and then choose “Join the network” -

press 

OK” key -

  enter into the Join the network mode. 

 

If  code  receiving  finished  in  16  seconds,  exit  code  receiving  mode  after 

three “beep” sounds, and then enter into code menu. 

 

Setup the user ID number for the new monitor. 

 

The  added  outdoor  unit(finished  clear  code),  under  the  standby  mode-

keep pressing ”call” key for 6 seconds until two “beep” sounds(“beep” once 

about 3 seconds) -

loosen the key to enter into Join the network mode. 

 

Outdoor unit make three “beep” sounds if receive code successfully, and as 

No. 2 outdoor unit. 

 

If  failed  to  receive  code in  16  seconds,  exit  receive  code mode  after  one 

“beep”  sound.  Enter  into  the  Code  Menu  (Outdoor  unit  enters  into  the 

standby mode) 

 

After code receiving finished, press ”OK” key on code give unit to exit the 

code give mode, enter into the code menu. 

 

Press  “EXIT”  key  to  return  to  MENU  gradually,  then  enter  into  standby 

mode 

 

After all units receive code finished, please use the No. 2 outdoor unit call 

all indoor  monitors,  if  all code matched,  receive  code  successfully;  if  not, 

clear  code  of  the  new  unit  (don’t  clear  the  code    giving  unit),  reform  the 

code giving and code receiving again. 

NOTE: 

1.Do not set same ID number for every indoor monitors and outdoor units. 

2.The original Password for code match menu is“0000”. 

3.Inform function: after match code, give code, receive code, clear code and reset 

ID number, please inform. Inform: tell all units the pieces and ID numbers in the 

system. 

4.Method of inform: outdoor unit calls all the indoor monitors (all indoor monitors 

should be matched), if there are two outdoor units, use the No. 2 outdoor unit to 

inform. 

 

 

Clear Code (Leave the network) 

Indoor monitor clear code method: 

Choose “network” option, press “OK” key to enter into password menu. 

 

Input  the  password  to  enter  into  code  match  menu  (original  password  is 

0000).If  you  input  wrong  password,  system  will  inform  you  “Password 

Error!”,  “Please  Input  Again!”,  enter  into  the  code  match  menu  until  input 

the right password 

Содержание TX-59

Страница 1: ...cent minute from German fixed line and 42 cent minute from mobile networks Free Email support technaxx de If you drill a hole in the wall please make sure that power cables electrical cords and or pip...

Страница 2: ...nd failure of charger caused by spilling water If the charger is in contact with water or other liquids disconnect the power supply immediately to prevent overheating fire electrical shock and failure...

Страница 3: ...come close to the door 8 One key display simple and convenient to use view the outdoor scenes and take photos or record videos under manual or automatically mode just by pressing down one key 9 Inter...

Страница 4: ...dby time 30 days Charge time 6 hours Outdoor unit External power 9 16V DC AC Power DC 9V Consumption 400mA Outline dimension 200 x 150 x 27 mm Weight 387 g Environmental temperature 0 C 40 C Placement...

Страница 5: ...ey when calling or monitoring as entrance key for exposure adjust as option key when calling extension monitor 4 EXIT monitor key work as monitor key for standby mode as exit key for MENU 5 MENU unloc...

Страница 6: ...t the line 3 Install rechargeable lithium battery to outdoor unit the unit starts up automatically 4 Put the top part of outdoor unit into the rainproof cover like the picture push the bottom part mak...

Страница 7: ...his product adopts MicroSD card as external storage device when there is no storage card in the product the photo taking and video recording functions are unrealizable If a self provided storage card...

Страница 8: ...itor In standby time mode press Door bell key to call the blue LED of the outdoor unit lights up with a sound of Du Du Blue LED of indoor monitor lights up the screen shows image and the unit rings fo...

Страница 9: ...ress photo taking key one press one photo the photos will be stored in MicroSD card Video Recording in monitor mode press video taking key start taking video press video taking key again to stop the v...

Страница 10: ...se POWER by pressing the USB only serves as charging function the indoor monitor works as normal Choose USB by pressing connect the monitor with the computer and read the files through computer Indoor...

Страница 11: ...tandby mode step by step NOTE Auto video If nobody replies in 5 seconds after connection the indoor monitor starts up auto video Factory default is auto video if manual video is set video recorded aft...

Страница 12: ...der the standby mode keep pressing call key for 6 seconds until two beep sounds beep once about 3 seconds loosen the key to enter into Join the network mode Outdoor unit make three beep sounds if rece...

Страница 13: ...y Enter into Backlight Time menu to set up standby time exit menu automatically after setup Press key increase and reduce standby time 10s 60s press OK key to setup and return to Backlight Time Setup...

Страница 14: ...is at low power the indoor monitor will show out low power to remind you to charge for outdoor unit This product can be charged by charger or by USB date line connected to computer or remove the lith...

Страница 15: ...r unit does not connect to the power Connect to the power Distance between outdoor unit and Indoor monitor is too far Adjust to appropriate distance Disturbed by magnetic field around Keep handset far...

Отзывы: