If two units match successfully in 16 seconds, indoor monitor displays
“Success”, outdoor unit makes “Beep- Beep-Beep” sounds, as the first
outdoor unit
■
If matching failed in 16 seconds, indoor monitor shows “failed”, the outdoor
unit makes ”Beep” sound
■
Press “EXIT” key on the indoor monitor, exit menu, enter into the standby
mode
Note: If failed match, rematch the code after connection, otherwise, rematch
the code after clear the code
1. Indoor monitor clear code method: refer to the menu function -
》
network -
》
Leave the network
2. Outdoor unit clear code method:
A. Transformer supply: long press “Reset” key about one second, code cleared
after a “tick” sound.
B. Battery supply: press “Reset” key and “doorbell key” at the same time till a
“Beep”, code cleared.
Pairing Additional Monitors or outdoor unit
NOTE: By default, the monitor is paired with the outdoor unit. These
instructions apply to paring a second or third monitor.
●
Start the network & Join the network (match more indoor monitors and
outdoor units ):
■
Choose “Start the network” on the old indoor monitor -
》
press “OK” key-
》
enter into “Start the network” mode
■
Added indoor monitor enters into the network menu -
》
choose “Leave the
network” -
》
press “OK” key -
》
and then choose “Join the network” -
》
press
“OK” key -
》
enter into the Join the network mode.
■
If code receiving finished in 16 seconds, exit code receiving mode after
three “beep” sounds, and then enter into code menu.
■
Setup the user ID number for the new monitor.
■
The added outdoor unit(finished clear code), under the standby mode-
》
keep pressing ”call” key for 6 seconds until two “beep” sounds(“beep” once
about 3 seconds) -
》
loosen the key to enter into Join the network mode.
■
Outdoor unit make three “beep” sounds if receive code successfully, and as
No. 2 outdoor unit.
■
If failed to receive code in 16 seconds, exit receive code mode after one
“beep” sound. Enter into the Code Menu (Outdoor unit enters into the
standby mode)
■
After code receiving finished, press ”OK” key on code give unit to exit the
code give mode, enter into the code menu.
■
Press “EXIT” key to return to MENU gradually, then enter into standby
mode
■
After all units receive code finished, please use the No. 2 outdoor unit call
all indoor monitors, if all code matched, receive code successfully; if not,
clear code of the new unit (don’t clear the code giving unit), reform the
code giving and code receiving again.
NOTE:
1.Do not set same ID number for every indoor monitors and outdoor units.
2.The original Password for code match menu is“0000”.
3.Inform function: after match code, give code, receive code, clear code and reset
ID number, please inform. Inform: tell all units the pieces and ID numbers in the
system.
4.Method of inform: outdoor unit calls all the indoor monitors (all indoor monitors
should be matched), if there are two outdoor units, use the No. 2 outdoor unit to
inform.
●
Clear Code (Leave the network)
Indoor monitor clear code method:
Choose “network” option, press “OK” key to enter into password menu.
■
Input the password to enter into code match menu (original password is
0000).If you input wrong password, system will inform you “Password
Error!”, “Please Input Again!”, enter into the code match menu until input
the right password