![Technaxx TX-214 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/technaxx/tx-214/tx-214_user-manual_1067022009.webp)
9
Model: TX-214,TX-215; Article No. 5023,5024; 10/2022
to make the number stop blinking to complete the setting.
Function 3: Press and hold the button for more than 10s until the screen shows F01.
At this point, you can restart the controller.
Function 4: Press and hold the button for more than 20s until the screen shows F02.
At this point, you can restore the controller to default settings.
Display Interface/Parameter Settings
System voltage type selection interface
The default battery voltage is 12V, i.e. the interface shows
U12V. If 24V is required, it should be set to U24V.
Setting method:
Press and hold for more than 2s until the
number flashes. Then, press to adjust. After adjustment, press
and hold for 2s again until the number no longer flashes. At
this point, the setting is complete.
Battery type settings
b01=Sealed lead acid battery (default)
b02=Gel battery
b03=Flooded lead acid battery
b04=Ternary lithium battery
b07=Lithium iron phosphate battery (LiFePo4)
b01 - b03 are multi-stage charging method
b04/b07 are two-stage charging method
Setting method:
same as above.
Load operating mode adjustment interface
[24H] - continuously power the load for 24.
[00H] - light control mode. The load is turned on or off by the
light control signal.
[1~23H] - time control mode. The load is turned on by the light
control signal and then turned off after a delay.
[C2A] - the load will work for 2 hours a day, stop for 15 minutes,
and keep cycling.
[C2d] - the load will work for 2 hours during the day, stop for