Technare DPA 28X Скачать руководство пользователя страница 3

 

TECNARE DPA 28X OWNER’S MANUAL

 

 

Tecnare Sound Systems – 

www.tecnare.com

 – [email protected] 

All operating and use of instructions should be followed. 

 

5. DO NOT USE THIS APPARATUS NEAR WATER 

Do not use the product near water. For example, near a bathtub, washbowl, kitchen sink, 

or laundry tub, in a wet basement, or near a swimming pool. 

 

6. CLEAN ONLY WITH DRY CLOTH 

Unplug  the  unit  from  the  wall  outlet  before  cleaning.  Do  not  use  liquid  cleaners  or  aerosol 

cleaners. Use a damp cloth for cleaning. 

 

7. DO NOT BLOCK ANY VENTILATION OPENINGS 

Slots and openings in the cabinet back or bottom are provided for ventilation, to ensure reliable 

operation of the limit and to protect it from overheating. These openings must not be blocked or 

covered.  The  openings  should  never  be  blocked  by  placing  the  product  on  a  bed,  sofa,  rug,  or 

similar surface. This product should never be placed near or over a radiator or heat source. This 

product should  not  be  placed  in  a  built-in  installation  such  as  a  bookcase  or  rack  unless  proper 

ventilation is provided or the manufacture's instructions have been adhered to. 

 

8. DO NOT INSTALL NEAR ANY HEAT SOURCES 

This  Product  should  be  situated  away  from  heat  sources  such  as  radiators,  stoves,  or  other 

products (including amplifiers) that produces heat. 

 

9. DO NOT DEFEAT THE SAFETY PURPOSE OF THE POLARIZED OR GROUNDING-

TYPE PLUG 

A  Polarized  plug  has  two  blades  with  one  wider  than  the  other.  A  grounding-type  plug  has  two 

blades  and  a  third  grounding  prong.  The  wide  blade  or  the  third  prongs  are  provided  for  your 

safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of 

the obsolete outlet. 

 

10.  PROTECT  THE  POWER  CORD  FROM  BEING  WALKED  ON  OR  PINCHED 

PARTICULARLY  AT  PLUGS,  CONVENIENCE  RECEPTACLES,  AND  THE  POINT 

WHERE THEY EXIT FROM THE APPARATUS. 

 

Содержание DPA 28X

Страница 1: ...TECNARE DPA 28X OWNER S MANUAL...

Страница 2: ...maintenance instructions in the accompanying literature Please read the manual To reduce the risk of electric shock do not remove the top cover or the rear section No user serviceable parts inside Re...

Страница 3: ...sofa rug or similar surface This product should never be placed near or over a radiator or heat source This product should not be placed in a built in installation such as a bookcase or rack unless pr...

Страница 4: ...ING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME For added protection for this unit during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall...

Страница 5: ...ONS 8 TECNARE PCC CONTROLLER ADVANCED SERIES USER MANUAL 9 1 INSTALLATION 9 1 1 SOFTWARE INSTALLATION 9 1 2 SETUP THE PC COMMUNICATION 9 2 USING THE PCC CONTROLLER ADVANCED SERIES 9 2 1 Overview 9 2 2...

Страница 6: ...crossover selections compressor Limiter USB and Ethernet port connection Precise frequency control is achieved with its 1 Hz resolution The DPA 28X can be controlled or configured in real time on the...

Страница 7: ...miter Configurable Clock Noise Generator Sound Analyzer Phase inverter per band Mute Via adjustable delay 4 FRONT PANEL FUNCTIONS 1 LCD Screen CH A Show all the necessary information to control de uni...

Страница 8: ...he unit is On Signal at the input and the input level is above the device s maximum headroom respectively 7 8 Ethernet connector Standard RJ 45 female socket 9 Power switch Controls power On Off 5 REA...

Страница 9: ...able 2 USING THE PCC CONTROLLER ADVANCED SERIES 2 1 Overview The Tecnare PCC Controller advanced series software application provides real time control and configuration editing for the DPA 28X using...

Страница 10: ...ns Menu Bar Network window Input section Output section 2 2 MENU BAR The following menus are available in the Menu Bar at the top of the screen FILE Load Preset Click this option to Load an existing p...

Страница 11: ...INDOW When the PC is connected to the unit the following information is shown at the upper left corner of the screen Temperature It shows the temperature of each output channel Limiter The limiter lig...

Страница 12: ...it ID and grouping Signal Generator Input Level Input Compressor General Setup 30 bands Graphic equalizer UNIT ID AND GROUPING It shows the units information connected to the PC the active one is the...

Страница 13: ...ecting active in the dropdown list a pink noise signal is generated by the 8 output channels The output level is controlled by the fader control INPUT LEVEL Main delay in ms meters or feet can be adju...

Страница 14: ...a reduced rate that is determined by the ratio setting Threshold This control determines the level at which the compressor begins to act on the incoming signal It is calibrated in decibels with a ran...

Страница 15: ...the general Setup module Presets RTC Setup Analyzer Network Pcc LAN Port Internet Router IP PRESETS By pulling down the Select Preset dropdown list 10 different preset saved in the unit can be select...

Страница 16: ...dio Analyzer window open and closed The following information is available in this window Display Allows the user to show hide the input and reference signals Parameters Mode The audio analyzer allows...

Страница 17: ...Blackman Smooth Is the frequency average None 1 3 1 6 1 12 1 24 Octave Input and Output Allows the user to choose the PC input and output device Pink noise Enable the pink noise generator Note that t...

Страница 18: ...e the spectral components either of the input signal given by a microphone connected to the PC or the reference signal output it is also possible to visualize both signal simultaneously TRANSFER FUNCT...

Страница 19: ...UAL Tecnare Sound Systems www tecnare com info tecnare com 19 PHASE RESPONSE It allows the user to analyze the phase response of an installation IMPULSE RESPONSE This tool provide the spectrum impulse...

Страница 20: ...rnet cable the user is able to control all the unit parameters from another location remotely For this purpose the remote user must input the PCC Lan Port and Internet Router ID of the local DPA 28X u...

Страница 21: ...TECNARE DPA 28X OWNER S MANUAL Tecnare Sound Systems www tecnare com info tecnare com 21 This section contains the following modules Crossover Graphic EQ Limiter Level Delay Phase inverter Mute...

Страница 22: ...ossover filters per output Three different kinds of filters can be selected Bessel Butterworth L R The order of the filter can be selecting by pulling down the Bypass dropdown list Second Order filter...

Страница 23: ...select Hi Pass Low Pass or band filter Frequency Ranges from 20 to 20 000Hz in 1Hz steps Bandwidth Ranges from 0 1 to 2 Octaves Level Ranges from 25dB to 25dB The user can also modify the equalization...

Страница 24: ...ontrols are continuously adjustable from 40dBu maximum limiting to 17dBu Bypass Turn the module in bypass mode Attack Ranges from 0 1 to 90ms Release Ranges from 2x to 32x LEVEL DELAY Level The output...

Отзывы: