Ensure that your receiver’s port is set to 162
The system will generate a general trap on any error flag and send an 8-bit
value indicating the type of error, as follows:
Bit
0(LSB)
Overdrive
Bit
1
High
VSWR
Bit
2
High
Temperature
Bit 3
High Speed Hardware Shutdown
Bit 4(MSB) High Input Level
As an example, the following is a screen shot of a high temperature fault
(Value 4).