Technalogix Ltd
.
VIII-8
POWER -
Tactile
button to turn carriers on and off.
NAVIGATE -
Tactile button to move between menu items, or to refresh the screen after it
has timed out.
SELECT-
Tactile button to select menu item, or to refresh the screen after it has timed
out.
RESET -
Tactile button to reset microcontroller in control board. Also clears existing
faults. The amplifier will come back on with the soft start feature.
RF IN –
RF input from modulator or processor. BNC connector, 50 ohm.
RF OUT –
100-watt RF output. Connects to inline wattmeter (not supplied) and antenna. N
connector, 50 ohm.
REMOTE PORT -
Port to monitor and control the amplifier externally. See “ Monitor and
Control” section for pin-out.
AC IN –
AC input to switching power supply.
AC BREAKER –
Resettable circuit breaker is used to protect against inrush currents and
high current draw from switching power supply. The thermal circuit breaker
is a single pole configuration.
AC ON/OFF -
AC rocker switch (SPST) to supply AC to the AC-DC switching power supply