III.a) Temperature Alarm

This protection activates only in the cycle of  

work

  (i.e. when the 

temperature   of   the   boiler   is   lower   than   the   Set   Temperature).   If   the 
temperature   does  not   increase   in  the   time  set   by   the   user   (see   sub-
chapter:   Alarm)   ,   alarm   is   activated:   the   feeder   and   the   fan   are 
automatically  turned   off,   (water   pump  is   turned   on/off   independenty), 
and the sound signalling is turned on. The screen projects an adequate 
message:

The regulator expects the button 

MENU

 to be pressed, after which 

the   alarm   is   turned   off.   The   regulator   returns   to   the   previously   set 
process of work.

III.b) Thermal Protections

It   is   an   additional   bimetallic   mini-sensor   (installed   next   to   the 

boiler’s sensor) which cuts off the feeder and fan’s exits in the case of 
reaching and exceeding the temperature of 90 degrees. It prevents water 
which is in the system from boiling in case of the failure in the work of 
the regulator.

III.c) Automatic Sensor Control

Alarm is activated in the case of failure in the work of the sensors of 

CH or CHW temperature or in the work of   worm. Adequate message 
about the failure is also projected on the screen, e.g.:

The   feeder   nad   the   fan   are   turned   off.   The   pump   is   turned   on 

independently of the actual temperature. The regulator i waiting for the 
button  

MENU

  to   be   pressed   after   which   alarm   is   turned   off   and   the 

regulator starts working again. 

- 14 -

A L A R M

NOINCREASE INTEMP

A L A R M
SENSOR FAILURE

Содержание ST-77

Страница 1: ...ST 77 Manual Guide...

Страница 2: ...of Economy Employment and Social Politics Dz U 03 49 414 from 12th March 2003 implementing decisions of Low Voltage Directiv 73 23 EWG and the Decree of the Ministry of Infrastructure Dz U 03 90 848 f...

Страница 3: ...he device etc one must make sure that the regulator is not live The device should be intstalled by a person with adequate electrical training and certificates Before starting the programmer one should...

Страница 4: ...mperature the regulator is in a cycle of work in which the fan works all the time fuel feeder working time is set up by the user both the time of work and the time of break have to be set up if the th...

Страница 5: ...buttons PLUS and MINUS Pressing button MENU takes user to the first level of the menu The projector shows first two lines of the menu One can move in ech of the menus by using buttons PLUS and MINUS...

Страница 6: ...other elements Pressing button MENU starts the fuel feeder The feeder works until button MENU is pressed again Pressing MENU turns the fan on off Pressing button MENU turns the water pump on off Pres...

Страница 7: ...n the boiler Wrong set up of both the feeder working time as well as the feeder break time may cause faults in the work of the boiler i e coal may not get burnt in full or the boiler may not reach the...

Страница 8: ...resis of the set temperature in the boiler It is a difference between the set temperature so the temperature the user wants to have in the boiler and the temperature that is in the boiler at a certain...

Страница 9: ...t these are the fan s gears The higher the gear the faster the fan works Gear 1 is fan s minimum speed and gear 6 is fan s maximum speed Changes between gears can be introduced by pressing buttons PLU...

Страница 10: ...ported until it reaches the the set temperature If the set temperature is reached CHW pump is turned off and the CH pump is turned on CH pump continues working until the temperature in the boiler drop...

Страница 11: ...se in the time set by the user alarm is activated the feeder and the fan are automatically turned off water pump is turned on off independenty and the sound signalling is turned on The screen projects...

Страница 12: ...rature of turning CH and CHW pumps on It is turned off after reaching the temperature set on the boiler CHW pump is turned on again after the temperature on the boiler drops 10 degrees II n Burning 12...

Страница 13: ...e fuel and the boiler Caution Wrong set up of the described functions may cause constant increase in the temperature The time of break of burning shouldn t be too short II o Producer s settings The re...

Страница 14: ...tections It is an additional bimetallic mini sensor installed next to the boiler s sensor which cuts off the feeder and fan s exits in the case of reaching and exceeding the temperature of 90 degrees...

Страница 15: ...C the regulator will turn the feeder and the fan on and it will work until reaching the set on the boiler temperature III e Temperature Safety Protections The regulator is equipped in an additional pr...

Страница 16: ...he effectiveness of the engines earthing pump CHW pump fan and feeder L p Specification Units 1 Current Supply V 230V 50Hz 10 2 Power Consumption W 4 3 Ambinet Temperature O C 0 40 4 Load of the Circu...

Страница 17: ...and surge tank that protect the boiler from boiling of water in the central heating system must be installed VI a Diagram of the regulator s cabling installation Additional attention has to be paid d...

Страница 18: ...regulator 10 II k Alarm 11 II l Function of the constant CH pump 11 II m Summer function 12 II n Burning 12 II o Producer s settings 13 III Safety Protection 13 III a Temperature Alarm 14 III b Therma...

Страница 19: ...arantee does not include faults that occurred due to the wrong use of the product or those that are the user s fault mechanical faults or those that appeared after atmospherical discharge overvoltage...

Страница 20: ...Notes...

Отзывы: