With this function, you can set the operation time for the fuel feeder. Set the
operation time according to the type of fuel and boiler used.
II.d) Feed Interval
With this function, you can set the stand-by time for the feeder, depending on
the type of fuel used in the boiler. Incorrect operation and stand-by times
may cause the boiler to malfunction, i.e. inability to burn all carbon and to
reach the setpoint temperature. Setting correct times will ensure correct
boiler operation.
II.e) Fan Operation in Sustain Mode
With this function, you can set the blow time in the sustain mode.
II.f) Fan Interval in Sustain Mode
- 7 -
22
o
c 56
o
c
C.H. ON
Feed Time
Feed Interval
00 min 40 sec
Feed Interval
22
o
c 56
o
c
C.H. ON
Feed Interval
Fan Sustain Duty
00 min 10 sec
Fan Sustain Duty
22
o
c 56
o
c
C.H. ON
Fan Sustain Duty
Fan Sustain Pause
30 min 00 sec
Fan Sustain Pause