Principle of operation

Microprocessor   regulator  

ST-22,24,30,80

  is   designed   for   controlling   the 

central   heating   boiler   equipped   with   air-blow   and   the   central   heating   water 
circulation pump. It keeps the set temperature by means of ventilator. When the 
temperature   on   the   stove   is   lower   than   30°C,   the   controller   is   in   the   lighting 
function. Then to turn on the controller (the ventilator) you should press the button 

manual work

. It will cause turning on the indicator light marked with 

manual work 

and   turning  on  the  ventilator.  This   function   will   be   turned  on  (active)  until  the 
temperature on the stove reaches the set temperature. Repeated pressing this 
button will cause turning off the controller from the lighting function (to manual 
work). When the controller reaches the set temperature it will change to the back-
up mode. In this mode the work of controller consist in turning on the air-blowing 
with the frequency that depends on users’ settings – that is the kind of the fuel 
being burned in the boiler.

The set temperature function

 

The set temperature it is the demanded temperature on the boiler. You can 

change the temperature by pressing the      button. It means that you increase the 
temperature. By pressing the button      you fall the temperature while the display 
pulsates. After 4 seconds on the display there is shown the temperature on the 
boiler.

The functions of the controller

The controlling of the revolutions function can be activated by pressing the 

option   button.  The   diode  of   “revolutions  control”   is  switching   on.  This   function 
controls the ventilator’s work rate. Range of adjustment is from 1 to 6 (it can be 
said  that   these   are  ventilator’s   gears).   The  biggest  the  gear   is,  the  faster   the 
ventilator is working. The first gear – it is a minimum speed of the ventilator and 6

th 

gear is a maximum speed of the ventilator.
To change the range of ventilator’s gears, press the button        and  

The  

air-blowing work

  function it is the time (seconds) of ventilator’s work. It is 

automatically turned on when it reaches the set temperature and after the time of 

burning break.

The  

blower’s speed

  is depended on setting of the controlling of the revolutions 

function. This function prevents from extinguishing of the boiler.

The air-blowing break function – it is the time (minutes) when the ventilator is  
turned off.  

The break between ventilator’s work is automatically turned on after 

reaching the set temperature. This function prevents from extinguishing the boiler.

START/STOP

Button  

MENU

  (start stop) is designed to turning the ventilator on and off 

during continual controller's work. If the boiler reaches the temperature over 30°C 
and it doesn't reach the set temperature, then the button functions as START - 
STOP. Using this function you can switch the ventilator on or off during its work. It 

5