background image

Controller advantages

• 

built-in temperature and humidity sensor 

• 

wall-mountable housing

• 

front panel made of glass

Current temperature is displayed on the screen. Use the Menu button 

(in the middle) to display current humidity. Press and hold the Menu 

button to enter the menu. 

DESCRIPTION

The EU-T-2.1 room regulator is intended for controlling the heating 

device. Its main task is to maintain the pre-set room temperature by 

sending a signal to the heating device when the room temperature has 

been reached. 

There are 2 color versions: white or black.

1. Display - current room temperature/humidity

2.  

<

3. Menu

4.  

>

HOW TO INSTALL THE 

REGULATOR

The regulator should be installed by a qualified person. 

WARNING

• 

Risk of fatal electric shock from touching live connections. 

Before working on the controller switch off the power supply 

and prevent it from being accidentally switched on.

• 

Incorrect connection of wires may damage the regulator!

The diagrams below illustrate how the regulator should be mounted.

How to install particular elements:

HOW TO CHANGE THE PRE-SET 

TEMPERATURE

The pre-set temperature may be adjusted in the EU-T-2.1 room regulator 

by means of buttons < >.

During inactivity, the screen displays current room temperature. Press < 

or > to display the pre-set temperature value - the digits start flashing. 

Use the buttons < > to adjust the value.

MENU FUNCTIONS

Press and 

hold

 the Menu button to enter the regulator menu. Use the 

buttons < > to navigate through menu functions.

1. Operation mode

The Out function enables the user to choose one of the regulator 

operation modes: heating (HEA) or cooling (Coo). Select Out and 

when the screen starts flashing, press the Menu button. The screen 

shows available operation modes (Coo, HEA). Use the buttons < > 

to select the mode. In order to confirm changes, wait for about 5 seconds 

or press the Menu button.

2. 

Battery

The Bat function enables the user to check the battery level (%). 

Select Bat and when the screen starts flashing, press the Menu 

button. The screen displays the battery level.  

3. Hysteresis

The His function enables the user to set the room temperature 

hysteresis within the range of 0,2°C to 4°C. Room temperature 

hysteresis defines the pre-set temperature tolerance in order to 

prevent undesired oscillation in case of small temperature fluctuation.

Example:

Pre-set temperature : 23°C 

Hysteresis: 1°C 

The room regulator reports that the temperature is too low when the 

room temperature drops to 22 °C. 

In order to define the pre-set temperature hysteresis, use the buttons < 

> and select a desired value. In order to confirm changes, wait for about 

5 seconds or press the Menu button.

 

4. Calibration

The Cal function enables the user to calibrate the sensor within 

the range of -10°C to +10°C. Select Cal and when the screen 

starts  flashing,  press  the  Menu  button.  The  screen  displays 

current calibration value. Use the buttons < > to adjust the value.  

5. Auto-lock

The Loc function enables the user to activate the key lock. 

Select  Loc  and  when  the  screen  starts  flashing,  press  the 

Menu button. Next, the regulator asks if you want to activate 

the key lock (yes/no). Select the answer using one of the 

buttons < >. Wait 5 seconds to confirm. When the lock is active, 

the keys are locked after a few seconds of inactivity. To unlock, 

press and hold both buttons < >. If the screen displays Ulc, it 

means that the keys have been unlocked.

6. Min/Max pre-set temperature

The Def function enables the user to restore factory 

settings. Select this function and when the screen starts 

flashing, press the Menu button. Next, the regulator asks 

if you want to restore factory settings (yes/no). Select the 

answer using one of the buttons < >. In order to confirm, wait for about 

5 seconds or press the Menu button.  

7. Factory settings

The Def function enables the user to restore factory settings. 

Select  this  function  and  when  the  screen  starts  flashing,  press 

the Menu button. Next, the regulator asks if you want to restore 

factory settings (yes/no). Select the answer using one of the buttons 

< >. In order to confirm, wait for about 5 seconds or press the Menu 

button. 

8. Exit the menu

To exit the menu, select the Ret option. The screen flashes for 3 

seconds and exits the menu. 

NOTE

In order to display the software version number, press and hold the 

registration button on the back of the housing. 

1

3

2

4

23

.2

84 mm

COM NO NC

25 mm

23

.2

84 mm

Отзывы: