Controller advantages
•
built-in temperature and humidity sensor
•
wall-mountable housing
•
front panel made of glass
Current temperature is displayed on the screen. Use the Menu button
(in the middle) to display current humidity. Press and hold the Menu
button to enter the menu.
DESCRIPTION
The EU-T-2.1 room regulator is intended for controlling the heating
device. Its main task is to maintain the pre-set room temperature by
sending a signal to the heating device when the room temperature has
been reached.
There are 2 color versions: white or black.
1. Display - current room temperature/humidity
2.
<
3. Menu
4.
>
HOW TO INSTALL THE
REGULATOR
The regulator should be installed by a qualified person.
WARNING
•
Risk of fatal electric shock from touching live connections.
Before working on the controller switch off the power supply
and prevent it from being accidentally switched on.
•
Incorrect connection of wires may damage the regulator!
The diagrams below illustrate how the regulator should be mounted.
How to install particular elements:
HOW TO CHANGE THE PRE-SET
TEMPERATURE
The pre-set temperature may be adjusted in the EU-T-2.1 room regulator
by means of buttons < >.
During inactivity, the screen displays current room temperature. Press <
or > to display the pre-set temperature value - the digits start flashing.
Use the buttons < > to adjust the value.
MENU FUNCTIONS
Press and
hold
the Menu button to enter the regulator menu. Use the
buttons < > to navigate through menu functions.
1. Operation mode
The Out function enables the user to choose one of the regulator
operation modes: heating (HEA) or cooling (Coo). Select Out and
when the screen starts flashing, press the Menu button. The screen
shows available operation modes (Coo, HEA). Use the buttons < >
to select the mode. In order to confirm changes, wait for about 5 seconds
or press the Menu button.
2.
Battery
The Bat function enables the user to check the battery level (%).
Select Bat and when the screen starts flashing, press the Menu
button. The screen displays the battery level.
3. Hysteresis
The His function enables the user to set the room temperature
hysteresis within the range of 0,2°C to 4°C. Room temperature
hysteresis defines the pre-set temperature tolerance in order to
prevent undesired oscillation in case of small temperature fluctuation.
Example:
Pre-set temperature : 23°C
Hysteresis: 1°C
The room regulator reports that the temperature is too low when the
room temperature drops to 22 °C.
In order to define the pre-set temperature hysteresis, use the buttons <
> and select a desired value. In order to confirm changes, wait for about
5 seconds or press the Menu button.
4. Calibration
The Cal function enables the user to calibrate the sensor within
the range of -10°C to +10°C. Select Cal and when the screen
starts flashing, press the Menu button. The screen displays
current calibration value. Use the buttons < > to adjust the value.
5. Auto-lock
The Loc function enables the user to activate the key lock.
Select Loc and when the screen starts flashing, press the
Menu button. Next, the regulator asks if you want to activate
the key lock (yes/no). Select the answer using one of the
buttons < >. Wait 5 seconds to confirm. When the lock is active,
the keys are locked after a few seconds of inactivity. To unlock,
press and hold both buttons < >. If the screen displays Ulc, it
means that the keys have been unlocked.
6. Min/Max pre-set temperature
The Def function enables the user to restore factory
settings. Select this function and when the screen starts
flashing, press the Menu button. Next, the regulator asks
if you want to restore factory settings (yes/no). Select the
answer using one of the buttons < >. In order to confirm, wait for about
5 seconds or press the Menu button.
7. Factory settings
The Def function enables the user to restore factory settings.
Select this function and when the screen starts flashing, press
the Menu button. Next, the regulator asks if you want to restore
factory settings (yes/no). Select the answer using one of the buttons
< >. In order to confirm, wait for about 5 seconds or press the Menu
button.
8. Exit the menu
To exit the menu, select the Ret option. The screen flashes for 3
seconds and exits the menu.
NOTE
In order to display the software version number, press and hold the
registration button on the back of the housing.
1