background image

TECH

 

 

 

I.

 

SAFETY

 

Before using the device for the first time the user should read the following regulations carefully. Not obeying the rules 
included in this manual may lead to personal injuries or controller damage. The user’s manual should be stored in a safe 
place for further reference. In order to avoid accidents and errors it should be ensured that every person using the device 
has familiarized themselves with the principle of operation as well as security functions of the controller. If the device is 
to be sold or put in a different place, make sure that the user’s manual is there with the device so that any potential user 
has access to essential information about the device.  

The manufacturer does not accept responsibility for any injuries or damage resulting from negligence; therefore, users 
are obliged to take the necessary safety measures listed in this manual to protect their lives and property. 

 

  WARNING 

 

High voltage! Make sure the regulator is disconnected from the mains before performing any activities involving 
the power supply (plugging cables, installing the device etc.). 

 

The device should be installed by a qualified electrician. 

 

The regulator should not be operated by children. 

 

  WARNING 

 

The device may be damaged if struck by a lightning. Make sure the plug is disconnected from the power supply 
during storm. 

 

Any use other than specified by the manufacturer is forbidden. 

 

Before  and  during the  heating  season,  the  controller  should  be  checked  for  condition of  its  cables.  The  user 
should also check if the controller is properly mounted and clean it if dusty or dirty. 
 

 
 

Changes  in  the  merchandise  described  in  the  manual  may  have  been  introduced  subsequent  to  its  completion  on 
24.02.2022.  The  manufacturer  retains  the  right  to  introduce  changes  to  the  structure.  The  illustrations  may  include 
additional equipment. Print technology may result in differences in colours shown. 

 

 

Care for the natural environment is our priority. Being aware of the fact that we manufacture 
electronic devices obligates us to  dispose of used elements and electronic equipment in a 
manner which is safe for nature. As a result, the company has received a registry number 
assigned by the Main Inspector of Environmental Protection. The symbol of a  crossed  out 
rubbish bin on a product means that the product must not be thrown out to ordinary waste 
bins. By segregating waste intended for recycling, we help protect the natural environment. 
It  is  the  user's  responsibility  to  transfer  waste  electrical  and  electronic  equipment  to  the 
selected  collection  point  for  recycling  of  waste  generated  from  electronic  and  electrical 
equipment. 

 

Содержание EU-RI-1

Страница 1: ...TECH 1 EU RI 1 ...

Страница 2: ... 9 3 Constant mode 10 4 Pre set day temperature 10 5 Day from 10 6 Pre set night temperature 10 7 Night from 11 8 Sensor hysteresis 11 9 Floor sensor 11 10 Underfloor heating hysteresis 12 11 Maximum floor temperature 12 12 Minimum floor temperature 12 13 Button lock 13 VII Regulator functions Menu 2 13 1 Registration 13 2 Built in sensor calibration 13 3 Floor sensor calibration 13 4 Software ver...

Страница 3: ...e device may be damaged if struck by a lightning Make sure the plug is disconnected from the power supply during storm Any use other than specified by the manufacturer is forbidden Before and during the heating season the controller should be checked for condition of its cables The user should also check if the controller is properly mounted and clean it if dusty or dirty Changes in the merchandis...

Страница 4: ...o the main controller when the room or floor temperature is lower than the pre set value The EU RI 1 regulator functions Maintaining pre set room temperature Manual mode Day night mode Constant mode Equipment Front panel made of glass Built in temperature sensor Possibility of connecting a floor sensor III INSTALLATION The room regulator should be installed by a qualified person EU RI 1 regulator ...

Страница 5: ...TECH 5 The room regulator should be connected to the heating device with the use of a four core cable included sample RS cable forged on one side The wiring diagram is presented below ...

Страница 6: ...the EU RI 1 to other devices in the system 1 The EU I 3Plus main controller 2 EU WiFi RS Internet module 3 EU 505 Internet module 4 EU 294 Room regulator 5 EU RI 1 Room regulator 6 EU 292 Room regulator 7 EU i 1M Valve 8 EU i 1 Valve 1 2 3 4 5 6 7 8 ...

Страница 7: ...ode In order to activate this mode press MENU and hold until a corresponding icon day night mode appears on the main screen Manual mode In this mode the user sets the temperature in the main screen view using PLUS and MINUS buttons The manual mode will be activated automatically after pressing one of these buttons Once this mode is activated the previously selected mode enters sleep mode and remai...

Страница 8: ...ticular parameters 5 MENU button press this button to enter the menu with operation parameters While editing parameters press MENU button to confirm the changes and move on to edit the next parameter NOTE Hold the MENU button for about 5 seconds to enter the second menu where it is possible to register the regulator in the main controller calibrate the temperature read from the room and floor sens...

Страница 9: ...3Plus to EU RI 1 By default TIM is set to OFF With the PLUS button you can set TIM to ON and set the time on the regulator In this case the time from the controller will not be taken into account In order to set the time enter the menu and press MENU button until the clock settings TIM appear on the screen Use PLUS and MINUS to set the hour and minutes Confirm by pressing MENU button confirm and m...

Страница 10: ...day temperature settings appear on the screen Use PLUS and MINUS to set the temperature Confirm by pressing MENU button confirm and move on to edit the next parameter or EXIT button confirm and return to the main screen view Changes will also be saved automatically after 5 seconds of inactivity 5 DAY FROM The Day from function defines the exact time when the daytime starts In order to set this par...

Страница 11: ...eresis settings appear on the screen Use PLUS and MINUS to set the desired hysteresis value Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view Changes will also be saved automatically after 5 seconds of inactivity 9 FLOOR SENSOR In order to enable or disable the floor heating press the MENU button until the floor heating screen appea...

Страница 12: ...teresis 2 C When the floor temperature drops to 23 C the underfloor heating will be enabled It will be disabled when the temperature reaches 25 C 11 MAXIMUM FLOOR TEMPERATURE In order to set the maximum floor temperature activate the underfloor heating and press MENU until the maximum floor temperature settings appear on the screen Use PLUS and MINUS to set the temperature Confirm by pressing MENU...

Страница 13: ...tion wait 30 seconds before registering another regulator 2 BUILT IN SENSOR CALIBRATION Calibration should be performed while mounting or after it has been used for a long time if the room temperature measured by the sensor differs from the actual temperature Calibration setting range is from 9 9 to 9 9 C with the accuracy of 0 1 C To calibrate the built in sensor hold the MENU button to enter the...

Страница 14: ...enter the second Menu Next keep pressing the MENU button until the default setting screen appears F00 This function is used to restore factory settings In order to do it change the flashing digit 0 to 1 NOTE Restoring factory settings will result in unregistering all devices from the main controller It will be necessary to register them again VIII TECHNICAL DATA Specification Value Room temperatur...

Страница 15: ... electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the regulation by the MINISTRY OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the regulation concerning the essential requirements as regards the restriction of the use of certain hazardous substanc...

Страница 16: ...TECH 16 ...

Отзывы: