Manual mode

 - the pre-set temperature may be adjusted 

manually in the main screen view using the buttons 

Holding the EXIT button while in being in manual mode exits this mode.

• 

Button lock - 

after pressing the Menu button, the 

Loc

 function 

appears.  Use  one  of  the  buttons 

 to select yes or no 

(enabling / disabling the button lock). In order to confirm, wait for 

about 5 seconds or press Menu. To unlock the buttons, hold both 

the buttons 

 until the padlock icon disappears. 

DESCRIPTION

The EU-R-8s Plus room regulator is intended for controlling the heating 

device. It cooperates with the zone controllers and communicates with 

them wirelessly.

Its main task is to maintain the pre-set room temperature by sending 

a signal to the heating device informing that the pre-set temperature 

has been reached. 

Colour versions available: white or black 

Controller features:

• 

large easy-to-read display

• 

front panel made of glass

• 

built-in  temperature  sensor,  humidity  sensor  and  floor  sensor 

(optional)

• 

time heating program

Current temperature is displayed on the screen. In order to switch from 

temperature screen to humidity screen, press EXIT. 

HOW TO INSTALL THE REGULATOR

The regulator should be installed by a qualified person.

The diagram below illustrates how to install particular elements: 

The diagram below illustrates how to install the floor sensor:

HOW TO REGISTER THE REGULATOR

In  order  to  register  the  regulator  in  the 

main controller, go to Zones > Registration 

as  described  in  the  manual  of  the  given 

controller.

Next,  briefly  press  the  registration  button 

in  the  EU-R-8s  Plus  regulator.  After 

reg

 is 

displayed,  briefly  press  the  registration 

button  again.  If  the  registration  process 

has been successful, 

SCs

 appears on the 

screen. If any errors occurred, the regulator 

displays 

Err

In order to register the regulator as a floor 

sensor, press the registration button twice.

NOTE

• 

Only 1 regulator may be assigned to 

one zone. 

• 

The regulator cannot be unregistered but only disabled. 

• 

If the user attempts to register a sensor in a different zone, the 

sensor is unregistered from the first

• 

zone and registered in the other one.

Holding the registration button on the controller for a few seconds will 

enable synchronization and consequently any change in the pre-set 

temperature in the main controller will automatically result in the 

same change in the regulator. Without synchronization, a change in 

the pre-set temperature in the main controller will cause a change in 

the regulator after a momentary delay. 

*

Holding  the  registration  button  while  turning  the  regulator  on  will 

calibrate the buttons.

MENU FUNCTIONS

In  order  to  enter  the  regulator  menu, 

HOLD

  the  Menu  button.  Next, 

press this button to switch between functions. 

1. Temperature sensor calibration

This function enables the user to check the value of temperature 

sensor  calibration.  The  calibration  setting  range  is  -10°C  to 

+10°C and it may be adjusted in the main controller.

2. Factory settings

The Fab function enables the user to restore factory settings. 

When this option has been selected, the screen starts flashing. 

Use the buttons 

 to change the last digit to 1. In order 

to confirm, wait for about 5 seconds or press the Menu button. 

3. Software version

This  function  enables  the  user  to  check  the  current  software 

version. The version number is necessary while contacting the 

service staff. 

HOW TO CHANGE PRE-SET 

TEMPERATURE

The pre-set temperature in the zone can be changed directly from the 

EU-R-8s Plus regulator using the buttons 

. To make it possible, 

the controller must be registered to the main controller. If the regulator 

displays 

Una

 after one of the buttons 

 is pressed, it means that 

the controller is not registered.

It is possible to change the pre-set temperature in the screen view with 

the pre-set and current temperature, using the buttons 

• 

After  setting  the  desired  temperature,  the  screen  displays  the 

time  when  the  temperature  value  will  apply.  This  time  can  be 

edited using the buttons 

• 

The 

OFF

 function disables the manually set parameters and it 

means that the settings resulting from the weekly schedule set in 

the main controller will apply. 

• 

If 

Con 

has been selected, manual settings will apply permanently 

regardless of the schedule settings.

If  the  pre-set  temperature  is  higher  than  the  current  temperature, 

heating  is  activated  and  the  flame  icon  appears.  This  icon  is  not 

displayed when the OFF function has been selected.

A/B - 84mm

C - 25mm

Fab

Czujnik

podłogowy

100cm

A

B

C

manual mode

heating/

cooling

battery level

signal 

strength

pre-set temperature

button lock

floor 

sensor

current

temperature