Manual mode
- the pre-set temperature may be adjusted
manually in the main screen view using the buttons
.
Holding the EXIT button while in being in manual mode exits this mode.
•
Button lock -
after pressing the Menu button, the
Loc
function
appears. Use one of the buttons
to select yes or no
(enabling / disabling the button lock). In order to confirm, wait for
about 5 seconds or press Menu. To unlock the buttons, hold both
the buttons
until the padlock icon disappears.
DESCRIPTION
The EU-R-8s Plus room regulator is intended for controlling the heating
device. It cooperates with the zone controllers and communicates with
them wirelessly.
Its main task is to maintain the pre-set room temperature by sending
a signal to the heating device informing that the pre-set temperature
has been reached.
Colour versions available: white or black
Controller features:
•
large easy-to-read display
•
front panel made of glass
•
built-in temperature sensor, humidity sensor and floor sensor
(optional)
•
time heating program
Current temperature is displayed on the screen. In order to switch from
temperature screen to humidity screen, press EXIT.
HOW TO INSTALL THE REGULATOR
The regulator should be installed by a qualified person.
The diagram below illustrates how to install particular elements:
The diagram below illustrates how to install the floor sensor:
HOW TO REGISTER THE REGULATOR
In order to register the regulator in the
main controller, go to Zones > Registration
as described in the manual of the given
controller.
Next, briefly press the registration button
in the EU-R-8s Plus regulator. After
reg
is
displayed, briefly press the registration
button again. If the registration process
has been successful,
SCs
appears on the
screen. If any errors occurred, the regulator
displays
Err
.
In order to register the regulator as a floor
sensor, press the registration button twice.
NOTE
•
Only 1 regulator may be assigned to
one zone.
•
The regulator cannot be unregistered but only disabled.
•
If the user attempts to register a sensor in a different zone, the
sensor is unregistered from the first
•
zone and registered in the other one.
Holding the registration button on the controller for a few seconds will
enable synchronization and consequently any change in the pre-set
temperature in the main controller will automatically result in the
same change in the regulator. Without synchronization, a change in
the pre-set temperature in the main controller will cause a change in
the regulator after a momentary delay.
*
Holding the registration button while turning the regulator on will
calibrate the buttons.
MENU FUNCTIONS
In order to enter the regulator menu,
HOLD
the Menu button. Next,
press this button to switch between functions.
1. Temperature sensor calibration
This function enables the user to check the value of temperature
sensor calibration. The calibration setting range is -10°C to
+10°C and it may be adjusted in the main controller.
2. Factory settings
The Fab function enables the user to restore factory settings.
When this option has been selected, the screen starts flashing.
Use the buttons
to change the last digit to 1. In order
to confirm, wait for about 5 seconds or press the Menu button.
3. Software version
This function enables the user to check the current software
version. The version number is necessary while contacting the
service staff.
HOW TO CHANGE PRE-SET
TEMPERATURE
The pre-set temperature in the zone can be changed directly from the
EU-R-8s Plus regulator using the buttons
. To make it possible,
the controller must be registered to the main controller. If the regulator
displays
Una
after one of the buttons
is pressed, it means that
the controller is not registered.
It is possible to change the pre-set temperature in the screen view with
the pre-set and current temperature, using the buttons
.
•
After setting the desired temperature, the screen displays the
time when the temperature value will apply. This time can be
edited using the buttons
.
•
The
OFF
function disables the manually set parameters and it
means that the settings resulting from the weekly schedule set in
the main controller will apply.
•
If
Con
has been selected, manual settings will apply permanently
regardless of the schedule settings.
If the pre-set temperature is higher than the current temperature,
heating is activated and the flame icon appears. This icon is not
displayed when the OFF function has been selected.
A/B - 84mm
C - 25mm
Fab
Czujnik
podłogowy
100cm
A
B
C
manual mode
heating/
cooling
battery level
signal
strength
pre-set temperature
button lock
floor
sensor
current
temperature