![Tech Works MC-IP Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/tech-works/mc-ip-series/mc-ip-series_manual_1066286021.webp)
1/24/2021
Tech Works MC-IP-Series System Planning & Installation Manual
Page 21 of 32
Number
is the port number 1 of 16 where Stations connect on this 116.
Description
is a description of the hardware connected to this port This is limited to 40
characters.
Location
is a reference to a general area such as cell block or wing where the Station is
located. This is limited to 30 characters.
Room
is the actual Room or Cell number where the hardware is located. This is limited to 10
characters.
Privacy Tone
is a check box to enable the Privacy Tone whenever this Station is called.
Privacy Tone Volume
sets the Privacy Tone level that comes out of the speaker into the
room or cell where it is located. Level options are 0-15.
Call Type
is the type of call to be sent from this Station and the associated ring style at the
ODC and is not implemented at this time.
Call Time Out
is the length of time that the system will wait to relay the call to another ODC.
A Relay is when a call is unanswered and a secondary answering location ODC rings with
that call after some designated amount of time. On a Relayed Call the originally intended
ODC will continue to ring even while the Relay ODC is ringing. The first ODC to answer will
clear the call from the entire system. Relayed Calls are not Forwarded.
Relay 1
is an ODC that calls from this Station should be Relayed to if calls are to be relayed.
Relay 2
is another ODC that calls from this Station should be Relayed to if calls are to be
relayed.