ELITE SERIES ROCKY COMPRESSOR
INSTALLATION
1.
ROCKY COMPRESSOR LOCATION REQUIREMENTS
The Elite Series Rocky Compressor location should be level, accessible and well ventilated.
If the Elite Series Rocky Compressor will be located in a confined space, provide adequate ventilation.
Electrical
(1) Line voltage must be within the limits of Figure 1 below. (Install a “buck-boost
transformer” if line voltage is not between these values.) Circuit breaker switches must
be 20 amp voltage.
(2)
Local code may require you to provide a quick disconnect (safety switch) for the
compressor.
(3)
See Figure 1 below for breaker size and line voltage.
CAUTION - Voltage must be 208/240 V or motor damage may occur.
CAUTION - Voltage must be 110/120 V or motor damage may occur.
2
Figure 1: Recommended Wire and Breaker Size
Dual Head Compressors
Model
Voltage
Amperage
Wire Size
Recommended
(Gauge)
Breaker Size
ACOR2D1
110/120
11
12
20
ACOR2D2
208/230
7.6
12
20
ACOR2D1Q
110/120
11
12
20
ACOR2D2Q
208/230
7.6
12
20