Tech Controllers EU-WiFi RS Скачать руководство пользователя страница 5

USER MANUAL 

 

IV.

 

FIRST START-UP 

 
In order for the controller to work properly, follow these steps while starting it for the first time: 
  
 

1.

 

Connect EU-WiFi RS to the main controller using an RS cable.   

2.

 

Connect the power supply to the module. 

3.

 

Go to the module menu and select WiFi network selection. A list of available WiFi networks 
will appear - connect to one of the networks by entering the password. In order to enter 
the password, use the arrows and select the right characters. Press the Menu button to 
confirm.  

4.

 

In the main controller menu go to  Fitter’s menu 

→ 

Internet module 

 ON and  Fitter’s 

menu 

 Internet module 

DHCP. 

 

NOTE 
It is advisable to check if the internet module and the main controller have the same IP 
address  (in  the  module:  Menu 

  Network  configuration 

  IP  address;  in  the  main 

controller: Fitter’s menu 

 Internet module 

  IP address). If the address is the same 

(e.g. 192.168.1.110), the communication between the devices is correct.  

 
 

V.

 

CONTROLLING THE SYSTEM ONLINE 

 
Once the devices have been connected properly, generate the registration code. In the module 
menu select Registration or in the main controller menu go to: Fitter’s menu 

 Internet module 

Registration.

 

After a while the code will appear on the screen. Enter the code in the application 

or at  

https://emodul.eu

     

  
  

NOTE  
The generated code is valid only for 60 minutes. If you fail to register within this time, 
a new code must be generated.  

  
  

NOTE   
It is advisable to use such browsers as Mozilla Firefox or Google Chrome.  

 

 
NOTE   
Using one account at 

emodul.eu

 it is possible to control a few WiFi modules.  

 
 
  
 
 
 
 
 
 
 
 
 
 

Содержание EU-WiFi RS

Страница 1: ...USER MANUAL 1 EU WiFi RS ...

Страница 2: ...Home tab 6 3 Zones tab 7 4 Statistics tab 7 VI Controller functions 8 1 Registration 8 2 WiFi network selection 8 3 Network configuration 8 4 Screen settings 8 5 Language 9 6 Factory settings 9 7 Software update 9 8 Service menu 9 9 Software version 9 VII Technical data 9 The pictures and diagrams are for illustration purposes only The manufacturer reserves the right to introduce some hanges ...

Страница 3: ... well as the insulation resistance of the cables The regulator should not be operated by children WARNING The device may be damaged if struck by a lightning Make sure the plug is disconnected from the power supply during storm Any use other than specified by the manufacturer is forbidden Before and during the heating season the controller should be checked for condition of its cables The user shou...

Страница 4: ...Main functions remote control of the system online checking the status of particular devices comprising the system editing the main controller parameters temperature log event log including alarms and parameter changes controlling many modules using one administration account email alert notifications III HOW TO INSTALL THE MODULE WARNING The device should be installed by a qualified person Incorr...

Страница 5: ...d the main controller have the same IP address in the module Menu Network configuration IP address in the main controller Fitter s menu Internet module IP address If the address is the same e g 192 168 1 110 the communication between the devices is correct V CONTROLLING THE SYSTEM ONLINE Once the devices have been connected properly generate the registration code In the module menu select Registra...

Страница 6: ...in the field labelled Module description Registering a new account 2 HOME TAB Home tab displays the main screen with tiles illustrating the current status of particular heating system devices Tap on the tile to adjust the operation parameters A screenshot presenting an example Home tab with tiles The user can customize the the home page by changing the layout and order of the tiles or removing the...

Страница 7: ... and the corresponding icons In order to do it go to the Zones tab Zones tab 4 STATISTICS TAB The Statistics tab enables the user to view the temperature charts for different time periods e g 24h a week or a month It is also possible to view the statistics for the previous months Statistics tab ...

Страница 8: ... confirm the password 3 NETWORK CONFIGURATION Normally the network is configured automatically The user may also conduct it manually using the following parameters of this submenu DHCP IP address Subnet mask Gate address DNS address and MAC address 4 SCREEN SETTINGS The parameters available in this submenu enable the user to customize the main screen view The user may also adjust the display contr...

Страница 9: ...ion when available 8 SERVICE MENU The parameters available in the service menu should be configured only by qualified fitters and access to this menu is secured with a code 9 SOFTWARE VERSION This function is used to view the controller software version VII TECHNICAL DATA No Specification 1 Supply voltage 5V DC 2 Operating temperature 5 C 50 C 3 Maximum power consumption 2 W 4 Connection with the ...

Страница 10: ... TECHNOLOGY of 24 June 2019 amending the regulation concerning the essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic equipment implementing provisions of Directive EU 2017 2102 of the European Parliament and of the Council of 15 November 2017 amending Directive 2011 65 EU on the restriction of the use of certain hazardous subs...

Страница 11: ...USER MANUAL 11 ...

Страница 12: ...USER MANUAL 12 ...

Отзывы: