II.

 

DEVICE DESCRIPTION

 

EU-295  room  regulator  is  intended  for  controlling  thermoactuators.  Its  main  task  is  to  maintain  the  pre-set  room 
temperature by sending a signal to the actuator (contact closing) when the room temperature is too low. 

EU-295 regulator functions: 

 

Maintaining pre-set room temperature 

 

Manual mode 

 

Day/night mode 
 
 

Controller equipment: 

 

Built-in temperature sensor 

 

Batteries 

 

Possibility of connecting a floor sensor 

 

Possibility of pairing with MW-1 (v2 version) 
 

III.

 

INSTALLATION 

 The controller should be installed by a qualified person. EU-295 controller may be installed on the wall. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание EU-295

Страница 1: ...1 EU 295 v2 v3...

Страница 2: ...VII Controller functions 9 1 Block diagram of main menu 9 2 Clock settings 9 3 Pre set day temperature 10 4 Day from 10 5 Pre set night temperature 10 6 Night from 10 7 Pre set temperature hysteresis...

Страница 3: ...ce may be damaged if struck by a lightning Make sure the plug is disconnected from the power supply during storm Any use other than specified by the manufacturer is forbidden Before and during the hea...

Страница 4: ...ing when the room temperature is too low EU 295 regulator functions Maintaining pre set room temperature Manual mode Day night mode Controller equipment Built in temperature sensor Batteries Possibili...

Страница 5: ...5 The room regulator should be connected to the heating device using a two core cable as illustrated below EU 295v2...

Страница 6: ...replaced at least once every heating season In order for the control circuit to operate properly it is necessary to provide the regulator with 230 V AC power supply as illustrated in the diagram IV FI...

Страница 7: ...the day The user presets the temperature values for both day time and night time as well as the time of entering day mode and night mode In order to activate this mode press EXIT and hold until a cor...

Страница 8: ...de and increases the pre set temperature After entering the menu this button is used to adjust parameters 5 MENU button hold this button in order to enter the controller menu While editing parameters...

Страница 9: ...next parameter or EXIT button confirm and return to the main screen view 1 BLOCK DIAGRAM OF MAIN MENU 2 CLOCK SETTINGS In order to set the time enter the menu and press MENU button until the clock se...

Страница 10: ...to define the pre set night temperature enter the menu and press MENU button until the pre set night temperature settings appear on the screen Use PLUS and MINUS to set the temperature Confirm by pre...

Страница 11: ...floor heating press MINUS Confirm by pressing MENU button confirm and move on to edit the next parameter or EXIT button confirm and return to the main screen view 9 MAXIMUM FLOOR TEMPERATURE In order...

Страница 12: ...ps below the minimum temperature the underfloor heating will be enabled It will be disabled after the floor temperature has reached the minimum value plus hysteresis value Example Minimum floor temper...

Страница 13: ...nutes When the time is over the pairing attempt will fail If EU 295v2 screen shows SCS and all the control lights in MW 1 are flashing simultaneously the registration has been successful the control l...

Страница 14: ...cerning the essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic equipment implementing provisions of Directive EU 2017 2102 of the...

Страница 15: ...ectromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the regulation...

Страница 16: ...16...

Отзывы: