Tech Controllers EU-280 Скачать руководство пользователя страница 19

Tech 

 

19 

 

 

Operation modes 

After clicking on this icon, you can easily change the pumps operation mode (in the boiler controller) 
between:  Home  heating,  Priority,  parallel  pumps,  summer  mode,  Floor  heating.  More  detailed 
descriptions of these operating modes can be found in the operation manual for the boiler controller. 
 
Submenu for the pellet controller:

 

 

Set temperature 

After clicking on this icon you can change the value of the 
set temperature on the boiler (you can do this by clicking 
on ‘view of parameters’ from the starting screen).  
 

 

Lighting 

By  clicking  on  this  icon  you  will  activate  the  process  of 
lightning the boiler. 
 

 

Extinguishing 

By clicking on this icon you will activated the process of extinguishing the boiler. 
 

 

Operating mode 

After clicking on this icon, you can easily change the pumps operation mode (on the boiler controller) 
between:  Home  heating,  Priority,  parallel  pumps,  summer  mode,  Floor  heating.  More  detailed 
descriptions of these operating modes can be found in the operation manual for the boiler controller. 
 
 

Submenu for the Installation Controller: 

 

Operating modes 

After clicking on this icon, you can easily change the pumps operation mode (with the boiler controller) 
between:  Home  heating,  Priority,  parallel  pumps,  summer  mode,  Floor  heating.  A  more  detailed 
description of these operating modes can be found in the operation manual for the boiler controller. 
 

V.f) Language Selection  

After clicking on the Language selection icon on the main menu you will see the panel used for changing 
the language for the user. 

 

 
 
 

 
 
 
 
 

V.g) Information about the Operating Program   

By  clicking  on  this  icon  the  display  will  show  the  boiler 
manufacturer's logo along with the software version. 

 
 

 
 
 
 

Содержание EU-280

Страница 1: ...Tech 1...

Страница 2: ...EU 280 user s manual 2...

Страница 3: ...on of the Controller 9 IVa Operating Principle 9 IVb Main Screen Description 9 V Controller Functions Menu Options 13 V a Time 15 V b Securities 16 V c Screen 17 V d Weekly Control 18 V e Boiler Contr...

Страница 4: ...not be held liable for damage caused by negligence WARNING Live electrical device Before any activities related to power supply connecting wires device installation etc you must ensure that the regula...

Страница 5: ...ful touch screen display allows for convenient operation of the regulator and modulation of its parameters The EU 280 room regulator enables Control of room temperature Control of the CH pump temperat...

Страница 6: ...on with the relevant qualifications WARNING There is a danger of fatal electrical shock from touching live connections You must disconnect the electrical connection and protect against accidental conn...

Страница 7: ...ccordance with colours of wires The cable is then connected to RJ12 connector which you should plug into the regulator power supply the place of connection is marked on the scheme as point 2 there is...

Страница 8: ...r in accordance with colours of wires This cable is then connected to the RJ12 connector and should be plugged into the v2 module the place of connection is marked on the scheme as point 2 there is an...

Страница 9: ...IVb Main Screen Description The controller is equipped with a large touch screen display The main screen displays the current state of basic parameters for the boiler Depending on the user s settings...

Страница 10: ...r will display an icon 8 Boiler 1 temperature current and set clicking the screen in this area will switch you to the menu which enables you to introduce changes to the set temperature of the boiler 9...

Страница 11: ...me and date 7 Right parameters panel 8 Buttons allowing change of active view of parameters panel 9 Access to the controller menu 10 Left parameters panel With the use of buttons allowing change of ac...

Страница 12: ...g on this panel it is possible to change the set temperature of the boiler Valves data panel View of the current temperature and set temperature of valve 1 2 3 or 4 after clicking on this panel it is...

Страница 13: ...clicking on this panel it is possible to change the pumps operation mode A selection can be made from among the following modes Home heating Priority parallel pumps summer mode with additional heating...

Страница 14: ...Screen Installation Screen Night from Hour Day from Hour Brightness During the Day Brightness at Night Weekly control Activated Disabled Settings Boiler Control Submenu Subject to the Type of the Mai...

Страница 15: ...t the current time according to which the regulator will then operate Date This function allows the user to set the current date according to which the regulator will then operate Alarm clock This fun...

Страница 16: ...ays on which the alarm clock is to be activated Controller screen view at the time of activation of the alarm clock V b Securities After clicking on the Securities icon on the main menu you will see t...

Страница 17: ...the screensaver option No screensaver or set the screensaver in the form of Clock the screen displays the clock Blank after the pre defined time of inactivity the screen goes blank Blanked only at nig...

Страница 18: ...e set deviation for subsequent hours just click on the symbol on the selected value and by means of the arrows copy selected settings for subsequent hours By clicking on the Copy icon you can copy the...

Страница 19: ...clicking on this icon you can easily change the pumps operation mode on the boiler controller between Home heating Priority parallel pumps summer mode Floor heating More detailed descriptions of these...

Страница 20: ...ionally be set after a longer period of use of the regulator if the room temperature measured by the internal sensor differs from the current temperature The regulation range is as follows 10 to 10 C...

Страница 21: ...e 5V DC Power consumption 1 3W Operating temperature 5o C 50o C Measurement error 0 5 C Room temperature adjustment range 5o C 40o C Room regulator power supply Power supply 230V 10 50Hz Max power con...

Страница 22: ...ting to electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the...