Tech Controllers EU-27i Скачать руководство пользователя страница 7

TECH 

 

 

again, when the temperature falls below the preset one by 

HCW hysteresis

 value.

 

 

 

HCW hysteresis 

The  HCW  pump  will  be  deactivated  after  the  decrease  in  the  temperature  in  circulation  below  the 
activation  temperature  by 

HCW  hysteresis

.  In  the  event  when  the  preset  temperature  is  reached            

and the pump is deactivated, pump re-activation will take place, when the temperature falls below the 
preset one, by 

HCW hysteresis

.

 

 

 

IV.f) 

 

Floor pump (settings)

 

   this setting shall be active, after choosing the floor pump (

MENU> pump type 2

). Using this function, 

parameters switching on the floor pump should be configured:

 

 

Floor pump activation temperature 

This is a threshold activation temperature value, after reaching it, a pump starts working. The pump 
will be deactivated when floor temperature falls below the activation temperature by 

floor hysteresis 

value

 or reaches the preset temperature

 

 

 

Preset floor pump temperature 

It is a floor pump temperature value, after reaching it, the floor pump is deactivated. The pump will 
be activated again, when the temperature falls below the preset one by 

floor hysteresis value

.

 

 

 

Floor pump hysteresis (

floor hysteresis

Floor pump will be deactivated after the decrease in temperature  in the circulation below the activation 
temperature by 

floor hysteresis

 value. In the event when the preset temperature is reached and the 

pump will be deactivated, pump re-activation will take place, when the temperature falls below the 
preset one by 

floor hysteresis

 value.  

 

 

IV.g) 

 

Factory settings

 

 

By  activating  the  option 

factory  settings

,  all  user's  own  device  settings  are  replaced  the 

settings saved by the manufacturer (it does not apply to servicing menu settings). From that moment, 
the own controller parameters may be set once again.

 

 

V. 

 

Servicing menu

 

In order to enter the servicing mode settings, network switch should be switched     to the item O, 
then output button should be pressed and, without the interval, network switch should be switched to 
the item I. After a few seconds, the regulator enters the servicing mode. In order to return to user 
menu (exit servicing menu), the controller should be deactivated and activated again.

 

 

1. Alarm temperature

 

 

This function applies to securing temperature circulation. It is a critical temperature value, at 

which the alert sound occurs along with the respective message on the display.

 

 

2. Alarm hysteresis

 

 

After the occurrence of an alert temperature, the possibility of switching it off takes place, after 

the decrease of temperature below alarm value by 

alarm hysteresis

 value.

 

 

3.Anti-stop

 

 

This setting allows for deactivating/activating 

anti-stop

 function.

 

 

4.Anti--freezing

 

 

This setting allows for deactivating/activating 

anti--freezing

 function.

 

 

Содержание EU-27i

Страница 1: ...TECH 1 EU 27i...

Страница 2: ...o electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the regula...

Страница 3: ...installing the de vice etc The device should be installed by a qualified electrician Before starting the controller the user shoud measure earthing resistance of the electric motors as well as the in...

Страница 4: ...supply time measurement is continued The controller has been also equipped with the function of protection against water freezing the so called anti freezing After the sensor temperature of the CH HC...

Страница 5: ...e directly from the main screen using plus and minus buttons HCW pump CH and HCW view It is possible to change the preset HCW temperature directly from the main screen using plus and minus buttons Flo...

Страница 6: ...the preset activation parameters ATTENTION In the event when there are two circulation pumps active pump 2 HCW or floor is turned off if their temperatures become equal Re activation will take place...

Страница 7: ...on temperature by floor hysteresis value In the event when the preset temperature is reached and the pump will be deactivated pump re activation will take place when the temperature falls below the pr...

Страница 8: ...takes place Working mode switched to CH only The second pump type is switched to No pump 4 Shorted sensor 2 Text on a display The activation of CH pump takes place Working mode switched to CH only The...

Страница 9: ...ut its duration Fastening of the controller should be also checked it should be cleaned from dust and other dirt Earthing effectiveness of the engines should be also measured Technical Data EU 27i Spe...

Страница 10: ...e you should ensure that plug is disconnected from the grid ATTENTION wrong connection of wires can cause the damage of the regulator IX a The diagram of connecting cables to the controller While asse...

Страница 11: ...ntroller functions 4 I 4 IV a Manual operation 4 IV b Pump type 2 5 IV c Working mode 5 IV d CH pump settings 6 IV e HCW pump settings 6 IV f Floor pump settings 7 IV g Factory settings 7 V Servicing...

Страница 12: ...EU 27i User s manual 12...

Отзывы: