Controller description

The 

EU-21 

regulator is intended for controlling CH pump.

Controller functions:

 - controlling CH pump

-  thermostat function

-  anti-stop function

-  anti-freeze function

Controller equipment:

- CH temperature sensor

- LED display

1.

 Controller display - during standard operation current temperature is 

displayed.

2.

  PLUS button

3.

  MINUS button

4. 

Power switch

5.

 MENU button - enter the controller menu, confirm the settings

6.

 Control light indicating manual mode

7.

 Control light indicating pump operation

8.

 Control light indicating power supply

Principle of operation

EU-21

  is  intended  for  controlling  the  central  heating  pump  (CH).  The 

main  task  of  the  controller  is  to  activate  the  pump  when  the  pre-set 

temperature value is exceeded and deactivate it when the CH boiler cools 

down (due to damping). Such characteristics prevent unnecessary pump 

operation, which saves electricity (up to 60% depending on the CH boiler 

use) and extends the life of the pump. It also enhances its reliability and 

reduces the maintenance costs. 

EU-21

  controller  offers  anti-stop  function  which  prevents  CH  pump 

stagnation.  The  pump  is  activated  every  10  days  for  1  minute. 

Additionally, every hour the time data is saved in non-volatile memory 

(EEPROM), which ensures that the timing is continued even in the event 

of voltage failure. 

Apart from that, the controller offers anti-freeze option protecting against 

water freezing. When the sensor temperature drops below 5˚C, the CH 

pump is enabled permanently. 

Both functions are active by default but it is possible do deactivate them 

in the service menu

Controller EU-21 performs thermostat funktions. Detailed 

parameter  specification  can  be  found  in  EU-21  manual,  on  the 

TECH website www.techsterowniki.pl.

How to use the controller

Use PLUS and MINUS buttons to adjust the pre-set temperature within the 

range of  5 to 98°C. The change is saved after a few seconds (flashing) 

and current sensor temperature appears. 

Press MENU to access two functions:

• 

Manual mode

Once manual mode has been selected by pressing MENU

 button, the corresponding control light goes on. In this 

mode, use PLUS button to enable the pump and MINUS 

button to disable it. This function enables the user to check 

if the pump works properly.

• 

Hysteresis   

This option is used to set the hysteresis of the pump 

operation. It is the difference between entering 

operation mode (activation threshold) and the temperature

 of returning to pause mode. 

Example: 

the  pre-set  temperature  is  60˚C,  the  hysteresis  is  3˚C  -  entering 

operation mode takes place at the temperature of 60˚C, return to pause 

mode takes place when the temperature drops to 57˚C.

How to install 

 The sensor should be installed on the CH boiler output with the use of a 

cable tie and protected from the influence of external factors with the use 

of an insulating tape (it cannot be dipped in any liquid). 

The pump power cord should be connected in the following way: blue and 

brown:230V, yellow-green (protective) should be earthed.  

The distance between the mounting holes is 110mm.

EU Declaration of conformity 

Hereby,  we  declare  under  our  sole  responsibility  that 

EU-21 

manufactured by TECH, headquartered in Wieprz Biała Droga 31, 

34-122 Wieprz, is compliant with:

• 

Directive  2014/35/EU  of  the  European  Parliament  and  of 

the  Council  of  February  26,  2014  on  the  harmonisation  of  the  laws 

of Member States relating to 

the making available on the market 

of electrical equipment designed for use within certain voltage 

limits (EU Journal of Laws L 96, of 29.03.2014, p. 357),

• 

Directive  2014/30/EU  of  the  European  Parliament  and  of 

the Council of February 26, 2014 on the harmonisation of the laws of 

Member States relating to electromagnetic compatibility (EU Journal of 

Laws L 96 of 29.03.2014, p.79),

• 

Directive  2009/125/EC  establishing  a  framework  for  the 

setting of ecodesign requirements for energy-related products,

• 

the regulation by the Ministry of Economy of May 8, 2013 

concerning  the  essential  requirements  as  regards  the  restriction  of 

the  use  of  certain  hazardous  substances  in  electrical  and  electronic 

equipment, implementing provisions of RoHS directive 2011/65/EU.

For compliance assessment, harmonized standards were used:

PN-EN 60730-2-9:2011, PN-EN 60730-1:2016-10.

Wieprz, 06.05.2019

 

   
    

1

  
   

4

   

5

 

    

6

    

7

    

8

    

3

    

2

NO.

SPECIFIKATION

1.

Power supply

230V ±10% /50Hz

2.

Maximum power consumption

2W

3.

Ambient temperature

5÷50

4.

Pump max. output load

0,5A

5.

Temperature 

measurement 

accuracy

1°C

6.

Sensor thermal resistance

-30÷99°C

7.

Fuse

1,6A

Service settings

In order to access the service settings, put the power switch in 0 position, 

press  MENU  and  holding  it  all  the  time  move  the  switch  to  1.  Release 

MENU button after a few seconds (b1 appears on the screen). 

Use PLUS and MINUS buttons to move to the next functions:

 •

Pump/thermostat

The regulator may serve as a pump or a thermostat.  

Use MENU button to select the operation mode:

– as a pump (the controlled device is enabled at the pre-set 

temperature and it is disabled when the temperature drops to

 the pre-set temperature minus hysteresis)

1

 – as a thermostat (the controlled device operates from the controller 

activation  until  reaching  the  pre-set  temperature;  it  is  enabled  again 

when the temperature drops below the pre-set value by the hysteresis). 

Anti-freeze

This function is used to enable/disable 

the anti-freeze function: 

0

 – OFF, 

1

 – ON

Anti-stop

This function is used to enable/disable 

the anti-stop function:

– OFF, 

– ON

Minimum pump activation threshold

This option is available only if thermostat function 

has been selected. The settings range is 0÷70°C

Notifications

bL +E5 

(alternately) - sensor failure

A5 

-anti-stop active

A2

 

- anti-freeze active

Technical data

  

b1

  

b2

  

b3

  

b4

 

 

o

1

 

 

o

2