Description

EU-19

  antystop    is  intended  for  controlling  the  central  heating  pump 

(CH).  The  pre-set  temperature  is  defined  using  a  potentiometer.  The 

main  task  of  the  controller  is  to  activate  the  pump  when  the  pre-set 

temperature  value  is  reached  and  deactivate  it  when  the  CH  boiler 

temperature drops by 20 C below the pre-set value. Such characteristics 

prevent  unnecessary  pump  operation,  which  saves  electricity,  extends 

the life of the pump and enhances its reliability. ST-19 controller also has 

an additional feature – ANTI-STOP, which prevents CH pump stagnation 

outside the heating season ( the pump is activated every 10 days for 1 

minute).

 

Controller functions:

• 

controlling CH pump

• 

anti-stop 

 

Controller equipment:

• 

CH temperature sensor

• 

Potentiometer for setting the desired temperature

 

Principle of operation

 EU-19

  antystop    is  intended  for  controlling  the  central  heating  pump 

(CH). The main task of the controller is to activate the pump when the pre-

set temperature value is exceeded and deactivate it when the CH boiler 

cools down (due to damping). Such characteristics prevent unnecessary 

pump operation, which saves electricity (up to 60% depending on the CH 

boiler use), extends the life of the pump. It also enhances its reliability 

and reduces the maintenance costs. 

ST-19  controller  offers  anti-stop  function  which  prevents  CH  pump 

stagnation.  The  pump  is  activated  every  10  days  for  1  minute. 

Additionally, every hour the time data is saved in non-volatile memory 

(EEPROM), which ensures that the timing is continued even in the event 

of voltage failure.

How to configure parameters

Pump  activation  temperature  is  adjusted  using  the  potentiometer 

within the range of 25⁰C - 85⁰C. The pump is disabled when the actual 

temperature  drops  by  2⁰C  below  the  pre-set  value  (set  up  using  the 

potentiometer).  It  prevents  periodical  pump  switching  due  to  slight 

temperature fluctuation as it would have a negative impact on the life 

of the pump.   

Apart from the potentiometer, the regulator also has two switches - one 

for activating the device (indicated by the power supply light) and the 

other for manual pump activation ( indicated by the manual operation 

light). 

1.Potentiometer

2.Control light indicating manual operation

3.Control light indicating power supply

4.Control light indicating pump operation

5.Power supply switch

6.Fuse 1,6A

7.Power cord

8.CH pump output

9.Temperature sensor

10.Manual operation switch

Installation & How to use the device

The controller should be installed by a qualified person.

The sensor should be installed on the CH boiler output with the use of a 

cable tie and protected from the influence of external factors with the use 

of an insulating tape (it cannot be dipped in any liquid). 

 

The pump power cord should be connected in the following way: blue and 

brown:230V, yellow-green (protective) should be earthed.  

The distance between the mounting holes is 110mm

TECHNICAL DATA

NO

SPECYFIKATION

1.

Power supply

230V ±10% /50Hz

2.

Maximum power consumption

2W

3.

Ambient temperature

5÷50

4.

Pump max. output load

0,5A

5.

Temperature measurement accuracy 1°C

6.

Sensor thermal resistance

-30÷99°C

7.

Fuse

1,6A

EU Declaration of conformity

Hereby, we declare under our sole responsibility that 

EU-19

 manufactured 

by  TECH  STEROWNIKI,  head-quartered  in  Wieprz  Biała  Droga  31,  34-

122  Wieprz,  is  compliant  with  Directive  2014/35/EU  of  the  European 

Parliament and of the Council of 26 February 2014 on the harmonisation 

of  the  laws  of  Member  States  relating  to  the  making  available  on  the 

market  of  electrical  equipment  designed  for  use  within  certain  voltage 

limits  (EU  OJ  L  96,  of  29.03.2014,  p.  357),  Directive  2014/30/EU  of 

the European Parliament and of the Council of 26 February 2014 on the 

harmonisation of the laws of Member States relating to electromagnetic 

compatibility (EU OJ L 96 of 29.03.2014, p.79), Directive 2009/125/EC 

establishing a framework for the setting of ecodesign requirements for 

energy-related products as well as the regulation by the MINISTRY OF 

ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the 

regulation concerning the essential requirements as regards the restriction 

of  the  use  of  certain  hazardous  substances  in  electrical  and  electronic 

equipment, implementing provisions of Directive (EU) 2017/2102 of the 

European Parliament and of the Council of 15 November 2017 amending 

Directive 2011/65/EU on the restriction of the use of certain hazardous 

substances in electrical and electronic equipment (OJ L 305, 21.11.2017, 

p. 8).
For compliance assessment, harmonized standards were used:

 PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10.

                       

                                                       