29
www.teca-eu.com
1-888-TECA-USA (832-2872)
TECA
Thru Mount
Group II, Catagory 2 [1] G
EEx p d [ia] ia IIB+H2 T4
307-680 BTU/hr
DIMENSIONS
Air Cooled
Air Conditioners
AHP-1200CXP
SPECIFICATIONS
VOLTAGE
PERFORMANCE
(VAC
CURRENT WEIGHT
TEMP.
OPERATING
MODEL
PART NUMBER
NOTES
RATING
50/60
AMPS.
LBS.(KG)
CONTROL
AMBIENT (°C)
(BTU/HR)
HZ)
AHP-1200CXP
0-3070-2-018
Cool Only
307-680
120
4.0
39(17.7)
OPT*
-20/+40
* Requires 3-32 VDC drive signal
The AHP-1200CXP is TECA’s first solid state air conditioner designed for use in hazardous environments in the
United Kingdom and European Union. The AHP-1200CXP features a unique air moving device that eliminates static
discharge that traditional fans can generate. A compressed air line is required for the air moving device. The
AHP-1200CXP has been successfully implemented with a purged enclosure and other approved equipment in
pharmaceutical, petrochemical and other similar applications.
Directive 94/9/EC with reference to EN50014:1997/A2:1999, EN50016:2002.
Procedure XF011, XF013
Group II, Category 2 [1] G EEx p d [ia] ia IIB+H2 T4 Ta=-20 °C to +40 °C
LISTING & CLASSIFICATION: