TEC EXHAUST FAN FLOW METER Скачать руководство пользователя страница 2

THE ENERGY CONSERVATORY WARRANTY

EXPRESS LIMITED WARRANTY

Seller warrants that this product, under normal use and service as described in the operator’s manual, shall be free 

from defects in workmanship and material for a period of 24 months, or such shorter length of time as may be specified 

in the operator’s manual, from the date of shipment to the Customer.  

LIMITATION OF WARRANTY AND LIABILITY

This limited warranty set forth above is subject to the following exclusions:

•  With respect to any repair services rendered, Seller warrants that the parts repaired or replaced will be free from 

defects in workmanship and material, under normal use, for a period of 90 days from the date of shipment to the 

Purchaser.

•  Seller does not provide any warranty on finished goods manufactured by others. Only the original manufacturer’s 

warranty applies.

•  Unless specifically authorized in a separate writing, Seller makes no warranty with respect to, and shall have no 

liability in connection with, any goods which are incorporated into other products or equipment by the Purchaser.

•  All products returned under warranty shall be at the Purchaser’s risk of loss. The Purchaser is responsible for all 

shipping charges to return the product to The Energy Conservatory. The Energy Conservatory will be responsible 

for return standard ground shipping charges. The Customer may request and pay for the added cost of expedited 

return shipping.  

The foregoing warranty is in lieu of all other warranties and is subject to the conditions and limitations stated herein. 

No other express or implied warranty IS PROVIDED, AND THE SELLER DISCLAIMS ANY IMPLIED WARRANTY OF 

FITNESS for particular purpose or merchantability.

The exclusive remedy of the purchaser FOR ANY BREACH OF WARRANTY shall be the return of the product to the 

factory or designated location for repair or replacement, or, at the option of The Energy Conservatory, refund of the 

purchase price.  

The Energy Conservatory’s maximum liability for any and all losses, injuries or damages (regardless of whether such 

claims are based on contract, negligence, strict liability or other tort) shall be the purchase price paid for the products. 

In no event shall the Seller be liable for any special, incidental or consequential damages. The Energy Conservatory 

shall not be responsible for installation, dismantling, reassembly or reinstallation costs or charges. No action, 

regardless of form, may be brought against the Seller more than one year after the cause of action has accrued.

The Customer is deemed to have accepted the terms of this Limitation of Warranty and Liability, which contains the 

complete and exclusive limited warranty of the Seller. This Limitation of Warranty and Liability may not be amended or 

modified, nor may any of its terms be waived except by a writing signed by an authorized representative of the Seller.

TO ARRANGE A REPAIR

Please call The Energy Conservatory at 612-827-1117 before sending any product back for repair or to inquire about 

warranty coverage. All products returned for repair should include a return shipping address, name and phone number 

of a contact person concerning this repair, and the purchase date of the equipment.

Содержание EXHAUST FAN FLOW METER

Страница 1: ...EXHAUST FAN FLOW METER OVERVIEW AND MANUAL ...

Страница 2: ... to the conditions and limitations stated herein No other express or implied warranty IS PROVIDED AND THE SELLER DISCLAIMS ANY IMPLIED WARRANTY OF FITNESS for particular purpose or merchantability The exclusive remedy of the purchaser FOR ANY BREACH OF WARRANTY shall be the return of the product to the factory or designated location for repair or replacement or at the option of The Energy Conserva...

Страница 3: ...ge for the Exhaust Fan Flow Meter is 10 to 124 cubic feet per minute CFM The device should be used with a TEC pressure and flow gauge such as the DG 1000 During the measurement procedure the Exhaust Fan Flow Meter is placed directly over the exhaust fan grille and is pushed up against the wall or ceiling so that the flexible gasket on the end of the metering box creates an air tight seal around th...

Страница 4: ...gauge kit Connect tubing to the gauge Connect the other end of the tubing to the T connector that is included with the TEC pressure and flow gauge kit Connect the two ends of the shorter tubing that is connected to the T connector to the Channel A and Channel B input taps on the TEC gauge Set the door position on the metering box The metering box comes with an adjustable opening which provides thr...

Страница 5: ...ding the power button until the green light comes on DG 700 Power on the gauge by pressing the On Off button 2 DG 1000 After the Home screen loads touch Gauge to open the Gauge app 3 DG 1000 Touch the mode area to open the Channel B Configuration menu DG 1000 power button Mode ...

Страница 6: ...t least 10 seconds so that the gauge auto zeros 3 Acceptable metering box pressures When using the Exhaust Fan Flow Meter the measured metering box pressure should never be greater than 8 0 Pa and never lower than 1 0 Pa Pressures above 8 0 Pa will commonly result in erroneous flow measurements because the metering box will tend to restrict air flow through typical residential exhaust fans Meterin...

Страница 7: ...etering box e g E2 or E3 If the door position is set to E3 the smallest opening and the metering box pressure is still below 1 0 Pa then the fan flow you are trying to measure is outside the low range of the instrument i e flow is less than 10 CFM 2 Channel B will show the air flow reading from the exhaust fan If the flow reading is fluctuating change the time average setting on the gauge by touch...

Страница 8: ...33 16 2 8 73 35 17 3 0 76 36 17 3 2 78 37 18 3 4 81 38 19 3 6 83 39 19 3 8 85 40 20 4 0 87 41 20 4 2 90 42 21 4 4 92 43 21 4 6 94 44 22 4 8 96 45 22 5 0 98 46 23 5 2 100 47 23 5 4 102 48 23 5 6 103 49 24 5 8 105 50 24 6 0 107 51 25 6 2 109 52 25 6 4 111 52 25 6 6 112 53 26 6 8 114 54 26 7 0 116 55 27 7 2 117 56 27 7 4 119 56 27 7 6 121 57 28 7 8 122 58 28 8 0 124 59 28 ...

Страница 9: ...ascals 0 5 E3 Flow CFM 10 07 x Metering box pressure in pascals 0 5 FLOW ACCURACY 10 of reading when used with a 1 accurate pressure gauge such as a DG 700 with a display resolution of 0 1 Pa 0 0004 inches of water FLOW RANGE Door position E1 44 124 CFM Door position E2 21 59 CFM Door position E3 10 28 CFM DIMENSIONS INSIDE 16 in L x 13 in W x 8 in D WEIGHT 3 lbs including handle ...

Страница 10: ...ms Windows 7 Windows 8 Windows 8 1 Windows 10 The drivers are available through Windows Update and the DG 500 and DG 700 drivers can be downloaded from TEC at software energyconservatory com TEC also offers mobile apps for Apple and Android devices that can be found in the Apple App Store or the Google Play Store Instructional Videos The Energy Conservatory TEC offers a variety of online instructi...

Отзывы: