background image

4.  The Feather Touch 3545 focuser is assembled to the OTA via the Focuser Mounting Flange
(fig. 6.1), and the Focuser Locking Collar (fig. 6.2). Loosening the focuser Locking Collar
allows the focuser to be rotated to any position relative to the telescope for ease of use. Once
the focuser has been positioned, it can be locked by turning the Locking Collar by either grab-
bing the grooves on this collar or by grabbing the optional Locking Stems and rotating the
Locking Collar clockwise until it is tight. The Locking Stems help to provide a better grip for
tightening the collar. They can however be replaced with the 10-32 Button Head Cap Screws
for a cleaner look if that is desired. NOTE: The focuser can be removed by loosening the
Locking Collar and unscrewing it completely and then pulling the focuser from the Adapter
Flange. This should only be done in rare circumstances and after contacting Starlight
Instruments or TEC because of possible damage that may result. 
5.  The Draw Tube (fig. 6.10) is fitted with 3 Stainless Steel wear strips (fig. 6.11). These
strips provide very low friction between the Housing (fig. 6.7) and the Draw Tube (fig. 6.10).
There is no lubrication required on these parts and an occasional cleaning of the Draw Tube
and the Stainless Steel Wear Strips with a damp paper towel to remove any grit or dirt is
advisable. The design is such, that as the focuser is racked in and out, the wiping action of the
Wear Strips on the mating surfaces tends to be self-cleaning. 
6.  The drag between the Focuser Housing (fig. 6.7) and the Draw Tube (fig. 6.10) can be
adjusted in using two adjustment methods. The Tension Adjustment Screw can be adjusted
using a 3/16 inch Allen wrench. Only a slight amount of rotation on this screw makes a
notable difference. Tightening this screw will allow larger loads to be lifted without the focuser
moving from the dead weight that may be attached to it and it will also decrease the amount
of deflection during positional changes during long exposures. Generally the factory settings
should be sufficient for most applications. 
In addition, adjustment can be done in a simpler way - by tightening a thumb screw (not
shown in picture, but easy to find) under the pinion assembly.
7.  In the event that different equipment such as: an optional Field Flattener or AP 2.7"
threaded End Cap (available from Starlight Instruments) is needed at the end of the focuser,
the Draw Tube End Cap (fig. 6.12) can be removed by loosening the (3) 6-32 socket head set
screw and then unscrewing the back.
8.  The 2 inch Eyepiece Holder does not use traditional thumb screws. This focuser uses an
Eyepiece Collet Locking Nut (fig. 6.14) and an Eyepiece Collet Sleeve. This design assures that
the eyepiece or imaging equipment is always precisely positioned and held into place during
imaging. To secure your eyepiece, insert the eyepiece into  the 2 inch opening making sure
that the nut has been turned counter clock wise to open the collet sleeve and push in the eye-
piece. Tighten the Collet Nut clockwise until it is tight. 

WARNING: Failure to tighten the Collet Nut can result in personal injury and/or
damage to equipment. Always make sure that the eyepiece is secured properly dur-
ing use. 
WARNING: Never point to the sun without proper filtering or without the Front Cover
in place. Failure to do so can result in personal injury or damage to the collet locking
sleeve and/or optics. The Collet Locking Sleeve is plastic and can melt if it gets too
hot. Possible fumes during melting can cause fogging or damage to the optics. 

9.  If a finder base is to be attached to the focuser housing make sure that the screws being
used are the proper length. 

WARNING: If they are too long they will contact the draw tube thereby causing dam-
age to the anodized surface of the draw tube.

WARRANTY

Starlight Instruments Incorporated guarantees this product to be free of any defects in materi-
al or workmanship for 3 years to the original owner. Disassembly of focuser outside of the
described items voids all warranties. 
Starlight Instruments Inc. • P.O. Box 68282, Schaumburg, IL 60168-0282. USA. 
Phone: 847-985-9595.

4

Содержание APO 140

Страница 1: ...TEC TEC APO APO 140 140 OWNER S MANUAL 2005 This telescope is closer to optical perfection more than any instrument I have ever used before R Renzi Italy ...

Страница 2: ...al length 980 mm Focal ratio 7 0 Image scale 3 5 arc min mm Resolution theoretical 0 8 arc sec Focuser Feather Touch 3545 Eyepiece holder 2 Collet type Focusing range 4 5 114 mm One turn focus travel Coarse 21 5 mm Fine 2 3 mm Back focus distance 6 7 170 mm Focuser load capacity 10 lb Tube assembly diameter 5 9 150 mm Baffle dia 7 178 mm TA length shortest 34 864 mm Balance point position 14 1 350...

Страница 3: ...r made of Aluminum push pull type It protects the optics and holds the baffle during transportation 2 Retractable Sliding Baffle This feature makes the OTA shorter for handling and transportation The open end of the baffle is rounded to improve aerodynamics of the front end of telescope Rounded edge creates less turbulence compared to straight cut baffles 3 Baffle flange It holds the baffle with f...

Страница 4: ...ing capability using a 9 1 Planetary Reduction Assembly coupled to a fine focus knob fig 6 9 The fine focus knob should be used once the image is close to focus and final tweaking is required 2 The two coarse focusing knobs fig 6 8 on each side of the focuser allow quick rough positioning of the eyepiece or imag ing equipment They are coupled to the rack and pinion set and the fine focus knob 3 Th...

Страница 5: ...ing positional changes during long exposures Generally the factory settings should be sufficient for most applications In addition adjustment can be done in a simpler way by tightening a thumb screw not shown in picture but easy to find under the pinion assembly 7 In the event that different equipment such as an optional Field Flattener or AP 2 7 threaded End Cap available from Starlight Instrumen...

Страница 6: ...me try of typical objective with appr RMS less than 1 50 and wave front error less than 1 10 The lenses are tested during manufac turing with different methods including test plates autocollimation test with an artificial star interferometry however we do not supply test results to avoid any kind of misinterpretations or numbers com petition between customers Each objective assembled in precision ...

Страница 7: ...ratching the tube DOVETAIL PLATE The Dovetail Plate like all other accessories for this telescope is CNC machined for lightness 320g and rigidity from aluminum stock and then black anodized for a tough corrosion free surface Though having the same width and hole pattern as Losmandy plates the TEC Dovetail Plate is only 9 long The shorter length not only allows it to be lighter but also provides yo...

Страница 8: ... parts only a Finder Base and a Finder Arm with knob 4 3 2 1 8 7 6 5 9 way The Finderscope Bracket contains the following parts Finder Base 1 that attaches to the focuser with two 8 32 screws Holding Knob 2 tightening this knob will hold the Finder Arm 3 with Finder Holder 4 to the Finder Base The Finder 9 is spring loaded with spring and screw covered by Spring Cover 6 The Finder holder has two 1...

Страница 9: ...late and Finder with bracket without removing it 2 AP diagonal 5 of 2 eyepieces Dimensions of AL case are 10 x 13 5 x 37 Weight net 13lb Weight with scope rings plate finder bracket AP diago nal 2 eyepieces appr 40lb ACCESSORIES Eyepiece Turret with Mahogany case Precision holder for five 1 25 eyepieces Diagonal mirror made of Sitall or Quartz Case safely holds six 1 25 eyepieces and I Turret Case...

Страница 10: ...ted field dia 1 6 3 long extension tube is required for straight through viewing 4 5 FOCUS TRAVEL With the 2 diagonal focusing tube is in the middle position Unvignetted field dia 1 4 camera depth 85 0mm With the Field Flattener focusing tube is in the middle position Unvignetted field dia 2 4 2 5 9 FOCUSING DIAGRAM ...

Страница 11: ...40 100 100 OTA price 4000 4250 4600 4750 OTA weight 18 lb 18 lb 18 5 lb 18 5 lb Tube dia 152 4mm 152 4mm 150 1mm 150 1mm Tube type drawn drawn machined machined Labeling no yes yes yes Color OTA Baffle white black white white white white white white Internal paint ultra flat black spray ultra flat black spray special coating special coating Internal baffles 3 4 4 4 Rings latches fixed fixed adjust...

Отзывы: