2. GENERAL INFORMATION  

 

National Standards, European Standards, local regulations, construction 
regulations, fire protection and safety regulations must be observed.  

During the installation, one must contact a person who is authorized for the 

chimney. The authorized person shall check the shape of the chimney connection 

of the product in the prescribed directions. In addition, the product installation 

and installation connection must be made by an authorized person. Before 

installing the stove, the lifting capacity of the installation ground should be 
checked whether it is resistant for the stove. In case of insufficient load resistance 

or low lifting capacity, suitable precautions must be taken (eg put a stove lifting 
plate).

 

 

3. SAFETY  

 

THE VENTILATION CONDITIONS WHERE THE PRODUCT WILL BE INSTALLED 
AND THE PROTECTION AGAINST FREEZING MUST BE TAKEN INTO 
CONSIDERATION.  

All the required standard examinations are tested for the product. The predicted 

parameters associated with combustion efficiency and exhaust gas emissions are 

observed. The stove type described in this manual has been tested according to the 

BA 1, DIN 1881 EN13240 standards, by an approved agency.  

Combustion chamber cover should be opened only to load the fuel. To avoid 

hazards, the combustion chamber must be closed.  For the efficient operation of 

the stove, there must be minimum of fresh air flow in the room where it is 
installed. 

 

CAUTION! The stove  can operate in conjunction with the existing multiple 
flue systems. This should not be an aspirator, ventilator etc.

 

The combustion of combustible materials causes heat energy to heat the stove 

surfaces (doors, door handles, flame monitor cover, side walls, front wall). These 

parts should not be touched without heat-protective gloves. 

 

CAUTION! Since the stove top surface might be hot, please do not put 
combustible materials on it. 

 

Содержание T-22

Страница 1: ...Installation Manual Central Heating Stove With Solid Fuel Model T 22 T 22 Plus Tested according to DIN EN 13240 For product efficiency and emission values see the declaration of conformity TR...

Страница 2: ...Mechanical Thermostat 7 4 2 4 Indicator Panel 8 4 2 5 Hot water for USE 9 4 2 6 Chimney Connection 9 4 2 7 Radiator Installation Connection 9 5 STOVE WORK PRINCIPLES 10 5 1 SUITABLE FUEL 10 5 2 FIRST...

Страница 3: ...ystem The thermostat in the product ensures that the circulation pump prevents automatically thus avoids the continuous consumption of the electricity Circulation pump works quietly and the electricit...

Страница 4: ...INST FREEZING MUST BE TAKEN INTO CONSIDERATION All the required standard examinations are tested for the product The predicted parameters associated with combustion efficiency and exhaust gas emission...

Страница 5: ...e best possible way However the stove or its accessories may still be damaged during transport Therefore after removing the stove from the package check whether it is complete and undamaged In case of...

Страница 6: ...inner edge of the fire chamber cover You can order the floor protection plate from seller when you require 4 2 STOVE INSTALLATION AND CONNECTION Product installation and assembly should be done accord...

Страница 7: ...the expansion tank please check the water level fill the water up to half of the expansion tank 4 2 2 Circulation Pump Circulation pump and bypass line should be installed to the input of the radiator...

Страница 8: ...ou can set the Mechanical Thermostat to the required temperature it should not be under 40 C otherwise it will not cause rapid combustion 4 2 4 Indicator Panel Electric Lamp The electric lamp starts t...

Страница 9: ...he chimney When the distance is short at least 1meter length flue pipe must be used and must be installed vertically The chimney to be used at the exhaust gas outlet can be multiple chimney connection...

Страница 10: ...bustion is listed in the attached information sheet CAUTION Since wood is not a permanently combustible fuel it is impossible to heat overnight CAUTION Never use wallpaper chipboard waste plastic or t...

Страница 11: ...If you burn it carefully you will prevent the formation of cracks in the insulating stones damage the paint and deterioration of the material The smell caused by the protective paint on the stove is...

Страница 12: ...ding to the Ministry of Environment Applications are for example Wood that is moist and treated with protection Thin sawdust Paper and paperboard except ignition Bark and hardboard waste Plastic and o...

Страница 13: ...ssembly scheme The boiler does not reach the desired temperature Check Fuel Type Chimney emission may be low Check the combustion chamber for sufficient air supply The desired temperature is not reach...

Страница 14: ...uct our company will try to repair this damage as soon as possible within the warranty period or it will replace the problematic part Only spare parts approved or supplied by the manufacturer must be...

Отзывы: