TROUBLE SHOOTING A
PROBLEM:
Unit does not operate and there is no BlueSENSOR light.
Check that the appliance is plugged into
and switched on to a mains supply that
corresponds to the rating plate at the rear
of the unit.
Check that the unit itself is switched on.
Lift the front panel and locate the on/off
switch on the underside of the power box.
The front panel should illuminate and the
automatic purge start.
Check the fuse in the plug
(Use only a 13Amp fuse to BS1362).
For US models check the fuse located
next to the on/off switch under the
front cover.
Check that the sensor window is free from
obstructions.
PROBLEM:
The BlueSENSOR light flashes continuously but no water flows?
This indicates temperature out of range possibly due to
use without water or freezing conditions. Ensure that the
unit is at room temperature and that the TEALtainer is full
and connected.
Switch off and on to reset
. After initial
purge the unit should function normally. If the problem
persists contact
TEAL. +44(0)121 770 0593
TROUBLE SHOOTING B
PROBLEM:
The unit seems to be working
but there is a reduced/ no water flow?.
Lift the front panel,
Switch off the unit
unclip the TEALtainer retaining wire and
and remove the TEALtainer. Disconnect the
pickup pipe by pushing the grey tab whilst
pulling upwards
If the waste bag is fully inflated empty it
into a sluice or
foul water drain
. Unscrew
the White cap and withdraw the pickup pipe.
Check the filter for obstructions. New bags
and filters are available from
TEAL
.
Ensure that the white capped bag is
filled
with cold fresh water to just below the neck.
Take care
when handling the full container.
Replace the twist cap and locate the
TEALtainer into the unit.
Lock the TEALtainer wire clip in position.
Ensure that the pickup pipe connector
snaps onto the white cap spout. Switch on
the unit, it will perform a 10 second cold
water purge to prime the system.
If water still does not flow, check the tap
nozzle for blockages. Clean with a pin or
carefully lever out and contact TEAL for a
replacement.
IMPORTANT: ALWAYS UNPLUG YOUR HYGIENIUS
BEFORE INSPECTING IT. IF A PROBLEM PERSISTS
CONTACT TEAL HOTLINE ON: +44 (0) 121 770 0593