Fill the unit with cold water until water can be seen
below the baffle.

Do not use pre-heated water as this may damage the
unit.

Do not overfill – if there is water above the baffle, use
the tap to reduce the water level before operating.

Close lid and ensure seal is fully engaged.

Connect to the vehicle’s power supply to switch on the
unit.

An orange LED indicates that the power is connected.

Allow to heat up for approximately 15 minutes.

The green LED will light to indicate water is at the
correct temperature.

Use tap to discharge water to wash hands.

If a continuous flow of water is required fully depress
the tap lever.

Waste water will drain through the drain hole and will
be held in the hollow bowl.

To empty the waste water, carefully detatch the bowl
from the main body of the Handeman Xtra and pour the
waste water through the water disposal slot into a foul
water drain.

When the water tank is empty of water the red LED will
light.

Disconnect the unit and allow to cool before refilling.

LED display

The unit has an LED display to indicate the status.

FLASHING GREEN

- unit on standby. Either waiting for

higher battery voltage or white wire to go to +12V.

SOLID GREEN

- unit at temperature.

SOLID AMBER

- unit heating.

SOLID RED

– no water / tilt fault.

FLASHING RED

- hardware fault.

Operating instructions

Empty the detachable bowl to a foul water drain and
rinse with clean water.

If unit is left unused for an extended period it is
recommended that it is emptied of water and
replenished with fresh water.

Clean all surfaces with an anti-bacterial wipe or
disinfectant paying particular attention to frequent
contact points. To clean the inside of the bowl, first take
off the removable rubber cover.

Do not use abrasive cleaners which may scratch the
external surfaces.

This unit must not be subjected to a high pressure water
jet.

It is recommended that the unit is cleaned with a
cleaning solution such as Milton according to the
instructions on a weekly basis.

Cleaning instructions

Towel holder

ref GENTWLHLDR

Soap bottle and bracket ref GENSOAPDISP/BRKT

Optional extras

At the end of its useful life, the
handwash unit should not be disposed
of in general household waste.

Units should be taken to a recycling
facility for electrical and electronic
items.

Please see WEEE regulations.

Disposal

Содержание Handeman Xtra

Страница 1: ...ng instructions E11 Approval No 10R 055528 Extension No 01 VCA registration number VCS377871 HMX 12 24v 2_2021 Manufactured by Teal Patents Limited Unit 2 Waterloo Avenue ChelmsleyWood Industrial Estate Birmingham B37 6QQ Telephone 0121 770 0593 Email enquiries tealwash com ...

Страница 2: ...nd washing only It is not designed for washing of crockery or other items 9 Water dispensed is not suitable for drinking 10 Water is dispensed at a temperature of 38 40 C 11 The appliance must be connected to a motor vehicle power supply 12 Do not stretch the cable and beware of sharp corners which may damage the cable 13 Unit must be mounted on the vehicle using suitable fittings 14 Unit should b...

Страница 3: ...licy of continual improvement in product quality and design The company reserves the right to change the specification of its models at any time Lower mounting holes Indicator light Reset button Bowl Baffle Water drainage slot Tap Mains cable Rear of bowl Back of Handeman Xtra Removable rubber cover ...

Страница 4: ...ch on The most common connection for the W W is at the ignition fuse though alternative connection points may be used Do not connect the W W to other vehicle systems that might have alternate power e g alarms as the Teal sink may not switch off The unit will switch off regardless of W W voltage when less than 11 9 volts are detected thus preserving the battery s integrity Consult the vehicle handb...

Страница 5: ...o a motor vehicle only It must not be used in any other application Before installation check that you have all the parts listed Please ensure that you use appropriate fittings before commencing Before commencing installation check that you have appropriate tools and a suitable workspace Failure to follow these instructions may result in personal injury damage to the product or damage to property ...

Страница 6: ...cate the status FLASHING GREEN unit on standby Either waiting for higher battery voltage or white wire to go to 12V SOLID GREEN unit at temperature SOLID AMBER unit heating SOLID RED no water tilt fault FLASHING RED hardware fault Operating instructions Empty the detachable bowl to a foul water drain and rinse with clean water If unit is left unused for an extended period it is recommended that it...

Страница 7: ...s for consequential loss or damage This guarantee does not effect your statutory rights as a consumer Guarantee No water dispensed Check water level in tank Water cold Check Orange LED is on If not check power supply If LED is on leave unit for 15 minutes to fully heat water If water is still cold unplug unit and return to supplier Red LED solid Unit cut out activated Low water Check water level R...

Отзывы: