Wall Mounting Or Free Standing
This unit has been designed for wall mounting or to be placed on any firm, flat,
level surface.
Before fixing to a wall, check that you have all the parts listed.
The rawlplugs provided are suitable for use in a solid brick wall. If mounting on an
alternative type of wall, ensure that you use appropriate fittings.
Before commencing installation check that you have appropriate tools and a
suitable workspace.
Failure to follow these instructions may result in personal injury, damage to the
product or damage to property.
Check that there are no hidden service pipes or cables in the area where you
intend to drill.
If you are unsure consult a suitable qualified installer.
Ensure that the position of the unit allows sufficient space for the opening of the
lid and the safe opening of the bowl.
Using the supplied template identify the locations for the 4 mounting screws.
Drill holes using an 7mm diameter drill bit.
Fit rawlplugs in each hole.
Mount the unit using the 4 screws and mounting spacers provided.
Note:
the bowl must be removed to provide access to the two lower mounting
holes. Lift the lid to access the upper mounting holes.
Do not overtighten fixings as this may damage the unit.
Take care not to drop tools or fixings into the unit.
Check that the unit is upright and level before filling.
Electrical Connection
This unit must be connected to a 110V power supply using the plug provided.
Do not attempt to replace the plug or hard wire the unit unless you are a
competent electrician.
Waste Water
All Handeman Xtra models have a removable bowl that retains all the dirty water.
There is no need for a separate waste pipe or waste water storage container.
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY INVALIDATE YOUR WARRANTY.
Installation
Fill the unit with cold water until water can be seen below the baffle.
Do not use pre-heated water as this may damage the unit.
Do not overfill – if there is water above the baffle use the tap to reduce the water
level before operating.
Close lid and ensure seal is fully engaged.
Connect to a 110V power supply to switch on the unit.
A green LED indicates that the power is connected.
Allow to heat up for approximately 15 minutes.
The green LED will light to indicate water is at the correct temperature.
Use the tap to discharge water to wash hands.
If a continuous flow of water is required, fully depress the tap lever.
Waste water will drain into the hollow bowl.
To remove waste water, detach the bowl and lift it out.
Tip the water from the water drainage slot on the front edge of the bowl into a
foul water drain and replace.
Rinse with clean water.
When the water tank is empty of water the red LED will light.
Refill the unit and press and hold the reset button for 2 seconds to reset the
Handeman Xtra 110V.
LED display
The unit has an LED display to indicate its status.
GREEN
- this indicates the water is heating up.
GREEN
- indicates the water is up to temperature and ready to use.
SOLID RED
– low water level. Refill and reset, holding the reset button for 2
seconds before releasing.
Do not press the reset button repeatedly.
FLASHING RED
- fault – see Troubleshooting Guide (overleaf ).
Operating instructions
Page 8
Page 9