Wall Mounting Or Free Standing

This unit has been designed for wall mounting or to be placed on any firm, flat,
level surface.

Before fixing to a wall, check that you have all the parts listed.

The rawlplugs provided are suitable for use in a solid brick wall. If mounting on an
alternative type of wall, ensure that you use appropriate fittings.

Before commencing installation check that you have appropriate tools and a
suitable workspace.

Failure to follow these instructions may result in personal injury, damage to the
product or damage to property.

Check that there are no hidden service pipes or cables in the area where you
intend to drill.

If you are unsure consult a suitable qualified installer.

Ensure that the position of the unit allows sufficient space for the opening of the
lid and the safe opening of the bowl.

Using the supplied template identify the locations for the 4 mounting screws.

Drill holes using an 7mm diameter drill bit.

Fit rawlplugs in each hole.

Mount the unit using the 4 screws and mounting spacers provided.

Note:

the bowl must be removed to provide access to the two lower mounting

holes. Lift the lid to access the upper mounting holes.

Do not overtighten fixings as this may damage the unit.

Take care not to drop tools or fixings into the unit.

Check that the unit is upright and level before filling.

Electrical Connection

This unit must be connected to a 110V power supply using the plug provided.

Do not attempt to replace the plug or hard wire the unit unless you are a
competent electrician.

Waste Water

All Handeman Xtra models have a removable bowl that retains all the dirty water.

There is no need for a separate waste pipe or waste water storage container.

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY INVALIDATE YOUR WARRANTY.

Installation

Fill the unit with cold water until water can be seen below the baffle.
Do not use pre-heated water as this may damage the unit.
Do not overfill – if there is water above the baffle use the tap to reduce the water
level before operating.
Close lid and ensure seal is fully engaged.
Connect to a 110V power supply to switch on the unit.
A green LED indicates that the power is connected.
Allow to heat up for approximately 15 minutes.
The green LED will light to indicate water is at the correct temperature.
Use the tap to discharge water to wash hands.
If a continuous flow of water is required, fully depress the tap lever.
Waste water will drain into the hollow bowl.
To remove waste water, detach the bowl and lift it out.
Tip the water from the water drainage slot on the front edge of the bowl into a
foul water drain and replace.
Rinse with clean water.
When the water tank is empty of water the red LED will light.
Refill the unit and press and hold the reset button for 2 seconds to reset the
Handeman Xtra 110V.

LED display

The unit has an LED display to indicate its status.

GREEN

- this indicates the water is heating up.

GREEN

- indicates the water is up to temperature and ready to use.

SOLID RED

– low water level. Refill and reset, holding the reset button for 2

seconds before releasing.

Do not press the reset button repeatedly.

FLASHING RED

- fault – see Troubleshooting Guide (overleaf ).

Operating instructions

Page 8

Page 9

Содержание Handeman Xtra 110V

Страница 1: ... Xtra 110V Installation and operating instructions Manufactured by Teal Patents Limited Unit 2 Waterloo Avenue ChelmsleyWood Industrial Estate Birmingham B37 6QQ Telephone 0121 770 0593 Email enquiries tealwash com www tealwash com ...

Страница 2: ...Important safety instructions page 4 Box contents page 5 Parts identification page 6 Installation page 8 Operating instructions page 9 Cleaning instructions page 10 Troubleshooting guide page 10 Optional extras page 10 Guarantee page 11 Disposal page 11 Technical specification page 12 ...

Страница 3: ...unit must be protected by a fuse rated at 3 amps 14 If used outdoors the equipment should be protected by an RCD 14 Cable should be placed in such a way to avoid trip hazards 15 Do not stretch the cable and beware of sharp objects which may damage the cable 16 Unit must only be used on a flat even surface It must be used only in an upright position Unit may be wall mounted if so use the provided f...

Страница 4: ...the specification of its models at any time Page 6 Page 7 Lid Plug hole Lid seal Baffle Its removal will void the warranty Carrying handle Indicator light Reset button Removable bowl Water drainage slot Tap Plug hole Rear of bowl Removable rubber cover Upper mounting holes Lower mounting holes Power cable 110V plug Carrying handle Rear of Handeman Xtra 110V ...

Страница 5: ... you are a competent electrician Waste Water All Handeman Xtra models have a removable bowl that retains all the dirty water There is no need for a separate waste pipe or waste water storage container FAILURETO FOLLOWTHESE INSTRUCTIONS MAY INVALIDATEYOURWARRANTY Installation Fill the unit with cold water until water can be seen below the baffle Do not use pre heated water as this may damage the un...

Страница 6: ...al Patents will not be liable to repair or replace goods where The fault has been caused through misuse accidental damage use contrary to the manufacturers instructions damage in transit or power surges The appliance has been used on a voltage supply other than that specified on the product Repairs have been attempted by someone other than Teal Patents or an authorised dealer The appliance is seco...

Страница 7: ...ty 3 3 litres Electrical Specification Operating voltage 110V 50Hz 60Hz Heater output 300W Operating current 2A IP rated IP34 Conforms to EN60335 1 A13 2017 Technical specification Teal Patents Ltd Unit 2 Waterloo Avenue Chelmsley Wood Industrial Estate Chelmsley Wood Birmingham B37 6QQ UK Tel 44 0 121 770 0593 www tealwash com Email enquiries tealwash com ...

Отзывы: