Page Mute/Page Pass Through 

 

 

 

 

Page Mute/Page Pass Through 

 

System behavior for Page Mute 

When a signal of adequate level (voltage) is sensed on the page mute input terminal, all other audio 

inputs to the Maxim™ III are muted to allow the building-wide page to be heard. The muting is applied to 

wireless microphones as well as computer, DVD, and all other line inputs. 

Effective for shipments after 

4/1/19 

of new units; serial numbers beginning with A19 and later (letter or 

number is A, B, C… and number is 19, 20, …). 

For older units see notes at the end of this section

New units: 

A paging system may be connected to the Maxim™ III. The panel labeling is 

based on a 25-

volt

 paging input signal. The Page Input impedance selector has three labeled switch positions (based on 

power draw at 25 V): 

• 

0.1 W DRAW 

(5000 Ω

 impedance) 

• 

1.0 W DRAW 

(620 Ω

 impedance) 

• 

MUTE OFF 

MUTE OFF 

disconnects the page input from the Maxim™ III. The other two settings select transformer 

taps inside the Maxim™ III for the speakers connected to the top left and lower right connections. These 

two connections are labeled A1 and A2 in Diagram A below. 

 
New Models: 

 

Switch Setting: 

0.1 W DRAW 

1 W DRAW 

MUTE OFF 

Impedance 

5000 Ω

 

620 Ω

 

Open circuit 

Power Draw at 25 V 

0.1 W 

1.0 W 

0 W 

Power Draw at 70 V 

1.0 W 

7.9 W 

0 W 

 

 

 

 

Older Models: 

Switch Setting: 

 

 

100 V 

 

 

70 V 

 

 

25 V 

Impedance 

5000 Ω

 

620 Ω

 

115Ω

 

Power Draw at 25V 

0.1 W 

1.0 W 

5.3 W 

Power Draw at 70V 

1.0 W 

7.9 W 

42 W 

 

Содержание Maxim III

Страница 1: ...Classroom Audio System Amplifier Mixer Receiver Installation Manual Maxim III...

Страница 2: ...nd uses only premium quality components to assure many years of reliable performance We appreciate your confidence by your selection of our product It is TeachLogic s intent to uphold that confidence...

Страница 3: ...ld be routed clear of foot traffic and supported clear of kinking or abrasion Object Protection Locate the operating unit so it will not be subjected to falling objects or water entry Internal Service...

Страница 4: ...Number Notes Contact If you should encounter an unresolved issue please contact the TeachLogic customer service department for further assistance 760 631 7800 support teachtogic com teachlogic com Li...

Страница 5: ...Installation Planning 7 Installation of Ceiling Sensor 8 Installation of Speakers 9 Integration 10 Page Mute Pass Through Integration 10 11 Fire Alarm Input 12 RS 232 Feature 13 Security Alert Featur...

Страница 6: ...ontrol 12 Lesson Capture Output Port 3 5 mm Back of IMA 520 receiver amplifier 1 Speaker Output 2 Fire Alarm Mute Input 3 Page Input 4 Page Sensitivity Control 5 Page Input Impedance Selector 6 ALS Ou...

Страница 7: ...Maxim III Installation 7...

Страница 8: ...sight keep away from direct light and electrical interference 3 Speakers Mark location for wall mount vs ceiling mount and confirm wiring run to the amplifier Ensure speakers evenly cover the listenin...

Страница 9: ...drop down style This will ensure 360 coverage and will minimize the transmission distance for more reliable performance Installation 1 Attach to T bar tail Installation 2 Concrete or Drywall Surface I...

Страница 10: ...rovides connection to both channels as does the bottom connector Each is wired in parallel to the other as shown below These are the acceptable wiring methods For speaker installation instructions ple...

Страница 11: ...connected to the Maxim III The panel labeling is based on a 25 volt paging input signal The Page Input impedance selector has three labeled switch positions based on power draw at 25 V 0 1 W DRAW 5000...

Страница 12: ...d ON send a page to test the mute function 7 Adjust the sensitivity control to ensure the Maxim III senses the page signal noting that some pages with quiet voices will require greater sensitivity set...

Страница 13: ...DVD etc will MUTE In the event of a fire this will help to lower the overall decibel levels and help students and staff hear the audible fire alarm tones instruction within the classroom This feature...

Страница 14: ...e teachlogic com resources page under Application Notes or directly at https TeachLogic com TeachLogic app notes rs 232 control Audio levels very often need to be adjusted when switching from computer...

Страница 15: ...Maxim III s selected mode Ordinarily the Maxim III will arrive new with the 4 pulse mode selected by default Installers should nevertheless confirm the mode upon installation if the security alert fe...

Страница 16: ...d the front panel power button in Red state for the duration of the mode switching process Figure 3 below 4 Move the RS 232 switch from ON to OFF and back again FIVE times Then release the front panel...

Страница 17: ...id interference Watch the how to video on teachlogic com resources Note Next steps are best performed with a second person as the listener Stand under or in front of a speaker Hold the microphone with...

Страница 18: ...s turned up to mid scale 12 o clock position On amplifier receiver ensure a green LED is illuminated just below Ch A or Ch B knob depending on the microphone used If no LED is illuminated Check the gr...

Страница 19: ...nput 1 aux input switchable to mic input Line Output Lesson Capture 3 5 mm with gain control front panel ALS 3 5 mm with gain control rear panel Page Input 2 pin Phoenix 25 V or 70 V normal Page Input...

Страница 20: ...Off Press Hold Mute Switch On Off Momentary Press blinks when muted Addt l Mic Gain Control Normal 3dB 6dB Audio Source Vol Gain Increase Decrease Channel Select A or B in battery compartment Externa...

Страница 21: ...P N UMM 500 20200903 541 E Main St Longmont CO 80501 teachlogic com support teachlogic com 760 631 7800...

Отзывы: