⑬  SELECT Key

 

        Used to combine with other keys for various operations

 

      

 Key Operation

 

    Operation

 

  ⑬SELECT Key +  ⑨↓Key Zero 

cancel 

  ⑬SELECT Key +  ⑪ENTER Key 

USER unit display 

  ⑬SELECT Key +  ⑧  →Key

 

                    ⑩  ←Key 

Set values or decimal point in 

USER unit display mode 

 

 

6.3 Internal Battery and Replacement 

The AAA type Oxiride dry‑cell battery is recommended but any other AAA type 

battery may be used. However the operating time will vary depending upon the 

battery used. The operating time of approx. 8 hours described in the 

specification is under the conditions of a ZR6(Y) Oxiride dry‑cell battery 

used at room temperature. When the voltage drops below 4V, [B] is displayed 

on the LCD. When it occurs replace the battery or switch to the external power 

source soon. When replacing the battery or switching to the external power, 

turn off the POWER switch ②  in the rear panel. (Note that it does not 

automatically switch to the external AC power source in battery operation)

 

 

Battery Storage

 

It is installed in the area where the lid in the rear panel slides. 

 

 

           

Rear View

 

 

 

 

 

 

 

            

  Slides to this direction 

MADE IN JAPAN

NO.

SERIAL

MODEL NO.

TEAC INSTRUMENTS CORP

DIGITAL STRAIN INDICATOR

5‑12V

0.3‑0.14A

TD−35

 

 

                               Battery Storage  

 

11

 

Содержание TD-35

Страница 1: ...Digital Strain Indicator Operation Manual Teac Corporation Ver 2006 4 18 P N D009185 00C 1...

Страница 2: ...e of this product according to the service standard prescribed by TEAC Corporation This TEAC warrantee shall also fully comply with any local product liability law Teac Corporation Headquarter Sales D...

Страница 3: ...Index 1 Overview 4 2 Features 4 3 Configuration 4 4 Standard Accessories 6 5 Specifications 6 6 Operation 8 7 Measuring Method 12 8 Miscellaneous Materials 15 9 External View 18 3...

Страница 4: ...ut value mV V for direct reading convenience This operates with a built in battery AAA type or external AC power supply using an AC adaptor 2 Features 1 Small and compact size 2 All necessary function...

Страница 5: ...5...

Страница 6: ...lay module LCD Character height approx 12mm Display frequency Approx 6 times second Peak hold Maximum value during measurement Calibration accuracy 0 1 F S or less FS 20000 10 strain Linearity 1 10 st...

Страница 7: ...Dimension 150mm W x100mm D x40mm H excluding umbo Weight Approx 500g including ZR6 Y dry cell battery 7...

Страница 8: ...for the display back light Note that twice as much power is consumed when it is turned on in battery operation INDICATION Display Unit Switch The switch to select whether the strain input is displaye...

Страница 9: ...the strain gauge or strain gauge sensor INPUT Sensor Input Connector The NDIS standard input connector for the strain gauge sensor Applicable plug model is PRC03 12A10 7M10 5 made by Tajimi Musen Pin...

Страница 10: ...ey Key Used to move the digit while setting value ENTER Key Used to set the value in various settings PEAK HOLD Key Used to select the peak hold operation It holds and displays the maximum value of th...

Страница 11: ...in the specification is under the conditions of a ZR6 Y Oxiride dry cell battery used at room temperature When the voltage drops below 4V B is displayed on the LCD When it occurs replace the battery...

Страница 12: ...n may occur such as rapid temperature or humidity changes 7 2 Wire Connection This is a strain indicator for measuring the strain gauge type sensor gauge output such as a load cell For the strain meas...

Страница 13: ...he rated capacity is a value found in the sensor s data sheet To change the decimal point position move the cursor to a desired decimal point position using or key press ENTER key and the character di...

Страница 14: ...range Countermeasure Refer to Zero Adjustment in the back of the material and adjust the bridge balance to the level smaller than 10000 10 strain AD OVER OVER Description The input level from sensor e...

Страница 15: ...weight is generated The zero adjustment range of TD 35 is 5mV V 10000 10 strain In case it does not meet the zero adjustment within this range as shown in the figure below the zero point shift resiste...

Страница 16: ...connect an appropriate resister RZ to one side of the bridge and record the displayed value then remove the resister When the indicator is replaced for a reason of servicing or so forth connect the sa...

Страница 17: ...Added resister value versus input conversion strain of the bridge circuit with 350 and 120 resistance List of switch settings on measurement items 17...

Страница 18: ...9 External View MADE IN JAPAN NO SERIAL MODEL NO TEAC INSTRUMENTS CORP DIGITAL STRAIN INDICATOR 5 12V 0 3 0 14A 18...

Отзывы: