53
10. BCD Data Output (TD-260T AC(BCD) / TD-260T DC(BCD))
The BCD data output is an interface for sending the TD-260T
displayed readings as BCD-coded data. The interface connects
the TD-260T to a computer, process controller, sequencer or
equivalent, for controlling, summarizing, recording or any other
processing purposes. The TD-260T internal circuit and external
connection circuit are electrically isolated with a photocoupler.
10-1. Panel
1
1
BCD connector
No.
I/O
Signal name
No.
I/O
Signal name
1
COM
19
COM
2
Output
1
20
NC
3
2
21
4
4
22
Output
Near Zero
5
8
23
Negative
(polarity)
6
10
24
OVER
7
20
25
P.C (stable)
8
40
26
STROBE
9
80
27
Input
Hold BCD
Data
10
100
28
Switch Data
Logic
11
200
29
NC
12
400
30
13
800
31
14
1000
32
15
2000
33
16
4000
34
Output
80000
17
8000
35
40000
18
10000
36
20000
Applicable connector: DDK 57-30360 or equivalent
NOTE
To reduce the unnecessary radio frequency emission, be
sure to install the provided ferrite core on the output cable
(for voltage or current).